Float Switch And Bracket; Water Valve; Drain Pump; Lower Spray Arm - Electrolux FRIGIDAIRE FDB125RH 2 Series Service Manual

24" built-in dishwashers precision wash system
Table of Contents

Advertisement

FLOAT SWITCH AND BRACKET

1. Disconnect dishwasher from electrical supply.
2. To remove float switch bracket, remove outer door
panel, kick plate, and wires to float switch. A single
Phillips screw secures the bracket to the tub.
3. Remove float switch by spreading mounting clips.

WATER VALVE

1. Disconnect dishwasher from electrical supply.
2. Remove outer door panel, kick plate, and wires.
3. Water valve is secured with two 5/16" hex screws.

DRAIN PUMP

1. Disconnect dishwasher from electrical supply.
2. Remove outer door panel and kick plate.
3. Remove hoses and wiring to drain pump.
4. Remove two screws securing drain pump to
mounting bracket.
5. Front housing can be removed by lifting lock tab
and turning housing counterclockwise about 45°
and lifting off.

LOWER SPRAY ARM

1. To remove lower spray arm, pull out on retaining
clips and lift up.

GLASS TRAP

1. To remove glass trap, lift handle up and raise
trap up and out of sump.

LOWER SPRAY ARM SUPPORT

1. To remove lower spray arm support, remove
spray arm and glass trap, then turn support 90°
clockwise and lift up.