8.4.5 Central booking/payment (2F)

The central payment or booking system shall provide an active (high) signal to the machine once
permission has been granted to start the machine. The signal must remain active (high) until the
machine starts. A feedback signal will be present on connection 18 and remain active (high) whilst
the program is running. The feedback signal is powered by 230V from connection 19 or external 24V.
25
1
2
0V
+24V
Electrical connection
1
2
3
4
5
6
1
2
Con 110
Central booking / payment
Start permitted
230V
Central booking / payment
Start permitted
24V
M1
M1
Central payment
Start permitted
1
2
3
4
5
6
1
2
3
Con 107
S1
S1
Status machine
2
Type of I/O card
F
Function I/O:s
Inp