Electrolux W575N Installation Manual page 35

Washer extractor
Hide thumbs Also See for W575N:
Table of Contents

Advertisement

W5250N
Heating alternative
Electric heated
Non heated/Steam heated
Max. permitted impendance* = 0.26 Ohm
W5330N
Heating alternative
Electric heated
Non heated/Steam heated
Max. permitted impendance* = 0.26 Ohm
* The impendance in the mains connected point in accordance with EN31000–3–11. If the
impendance in the mains connected point is higher than stated, check with the power supplier.
Electrical connection
Main voltage
200V 3 ~
220–240V 3 ~
220–240V 3 ~
380–415V 3 ~
380–415V 3 ~
440/480V 3 ~
200V 3 ~
Main voltage
200V 3 ~
220–240V 3 ~
380–415V 3 ~
440/480V 3 ~
200V 3 ~
440/480V 3 ~
Hz
Heating power
kW
50/60
12.5
50/60
9.1–10.8
50/60
15.1–18.0
50/60
9.0–10.8
50/60
15.0–17.9
60
18.0
-
50/60
Hz
Heating power
kW
50/60
14.4
50/60
16.6–19.8
50/60
16.5–19.7
60
21.0/22.8
-
50/60
-
60
Total power
Recommended
kW
fuse
A
13.3
50
9.8–11.6
35
15.9–18.8
50
9.8–11.5
25
15.8–18.7
35
18.8
35
1.1
10
Total power
Recommended
kW
fuse
A
15.6
50
17.8–21.0
63
17.1–20.9
50
22.2/24.0
50
1.2
10
1.2
10
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

W585nW5250nW5105nW5330nW5130nW5180n

Table of Contents