Connection of external dosing systems
6.2.3 Outputs
Connect the power supply (e.g. 24V DC) for the external liquid supplies to 9 and 10. If an internal
power supply (from the machine) is being used, it can be taken from 1 (N) and connected to 9 and
from 2 (L) and connected to 10. Max load on the outputs 0.5 A.
Signals for external liquid supplies 1-5 are connected to 12-16 where connector:
12 = Signal 1
13 = Signal 2
14 = Signal 3
15 = Signal 4
16 = Signal 5
⑰
6M14
-
Signal 1
Signal 2
Main wash
Signal 3
Softener
Signal 4
Mop last rinse
Signal 5
Bleach
6F01
6R01
Pre-wash
Pre-wash
Main wash
Main wash
Softener
Softener
Desinfection
Pr 1 last rinse
Bleach
Bleach
6F02
Other programs
Pre-wash
Pre-wash
Main wash
Main wash
Softener
Softener
-
Mainwash
Bleach
Bleach
27
fig.6236B