12. Auto White Balance & LV Standard Data Input
Adjust the white balance reference at 3200K, and adjust the normal
coefficient of the light value.
Subject
Clear chart
(Color reproduction adjustment
frame)
Measurement Point
Display data of page 1 (Note 4)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
1C, 1D, 28 to 2B
Specified Value
0FF0 to 1010
Note 1: This adjustment should be carried out upon completion of " Color
reproduction Adjustment".
Note 2: After the power is turned on, this adjustment can be done only
once.
Note 3: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note 4: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Switch setting:
1) POWER .................................................................. CAMERA
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM ............................................................. OFF
Adjusting method:
Order Page Address Data
1
0
01
01
2
6
01
11
3
6
01
0D
4
6
02
5
F
11
03
6
F
10
2E
7
1
Note 5: The adjustment data will be automatically input to page: F, address:
1C, 1D, 28 to 2B.
Processing after Completing Adjustments
Order Page Address Data
1
6
01
00
2
F
10
00
3
F
11
00
4
0
01
00
5
RadarW
RadarW
RadarW
RadarW
RadarW
Display data
Procedure
Set the data.
Set the data, and press PAUSE button.
Set the data, and press PAUSE button.
Check that the data changes to
"01". (Note 5)
Set the data, and press PAUSE button.
Set the data, and press PAUSE button.
Check that the display data
(Note 4) satisfies the specified
value.
Procedure
Set the data, and press PAUSE button.
Set the data, and press PAUSE button.
Set the data, and press PAUSE button.
Set the data.
Perform "Auto White Balance
Adjustment".
5-26