5.
Data Initialize Procedure
The following explains the adjustment procedure using the adjustment program (SMAP), following the order of items on PC
display.
Refer to "4. Starting Adjustment Program (SMAP)" in advance, start SMAP and display the main menu on PC display.
In actual work, it is possible to adjust one item independently.
Note: If error message appears on PC display during adjustment, perform troubleshooting, referring to "10. Error Messages".

5.1 Data Initialize

This procedure initializes the data in EEPROM (including the adjustment data).
Any time you replace the PC circuit board (containing EEPROM) or EEPROM, be
sure to perform this procedure. [Generally, this procedure is not necessary after
replacing other circuit board (components).]
Important:
After completing this adjustment, be sure to perform all adjustment items as
follows.
Procedure:
1) Input A to PC on the main menu screen.
2) The screen for verifying the initialization will appear: Input Y to PC. (*1)
3) Follow the instructions on PC display thereafter.
*1: Entering N on the screen for verifying initialization will restore the
data main menu screen.
3 - 6
Main menu
***********************************************************
MANUAL ADJUSTMENT PROGRAM
***********************************************************
[A]
DATA INITIALIZE
[B]
ELECTRIC VOLUME
[C]
ADJUSTMENT
[D]
AUTO FOCUS
[E]
SPOT NOISE
[ESC] END
Please select [A] - [F] or [ESC]
Input A.
Screen for verifying initialization
<< DATA WRITING >>
START TO SEND DATA. (Y/N)
Input Y.
Follow the instructions on PC display