Advertisement

Electrical connection

Electrical connection U.K.
All electrical work must be carried out
only by a competent person in accord-
ance with local and national regulations.
This washer extractor is supplied as
standard for connection to either:
230 - 240 V single phase supply
or:
415 V 2 phase + N supply.
The machine is not convertible.
The voltage, rated load and fuse rating
are given on the data plate. Please en-
sure these match the site mains supply.
Connection should be made via a suit-
able isolator which complies with na-
tional and local regulations, and the
on/off switch should be easily ac-
cessible for servicing work. For extra
safety it is advisable to install a residual
current device with a trip current of
30 mA.
Important
For 415 V 2 phase connection the ma-
chine is supplied with a 4- core cable
in the following colours:
Black = live
Brown = live
Blue
= neutral
Green and yellow = earth.
If a 3 phase supply is provided on site,
then one of the phases is not used.
WARNING
THIS APPLIANCE MUST BE EARTHED.
40
German standard version
The machine is supplied as standard
for connection to 400 V 2-phase + N
supply.