TEV LIMITED - HL/HLR SPLIT SYSTEMS The HL/HLR range of split systems comprises the 526 series HL indoor unit with in-built electromechanical controls, the 527 series HLR indoor unit with hard wired remote control, the 550 series outdoor condensing units and the 551 series heat pump outdoor units.
Page 3
HL/HLR INDOOR UNITS Model HL/HLR HEIGHT mm WIDTH mm 1210 1360 1560 DEPTH mm WEIGHT kg CONDENSING UNITS Model MCU(+) 90 MCU(+) 100 MCU(+) 130 MCU(+) 165 HEIGHT mm 1080 1080 WIDTH mm 1090 1090 1090 DEPTH mm WEIGHT kg 75 (78*) * Single phase HEAT PUMP OUTDOOR UNITS...
PRODUCT SELECTION Combinations of indoor unit and condensing/heat pump unit can be chosen to give either air conditioning or heat pump systems. UNIT COMBINATIONS Air Conditioning Systems Heat Pump Systems HL/HLR MCU(+) HL/HLR MCU(+) MHPUE AIR CONDITIONER PERFORMANCE DATA (All duties in kW) UK CONDITIONS EUROVENT (NEMA) TROPICAL...
ELECTRICAL DATA (Cooling Data rated at EUROVENT (NEMA) conditions) (Heating Data rated at 20°C/12°C indoor; 7°C/6°C ambient) a) R22 Air Conditioning Systems Single Phase Supply 230Volts - 50Hz Three Phase Supply 400 Volts - 50Hz SYSTEM SYSTEM INPUT FULL LOAD AMPS INPUT FULL LOAD AMPS MODEL...
Page 7
Electrical Loads (At 230 Volts 50 Hz 1Ph or 400 Volts 50 Hz 3PhN) HL/HLR FAN MOTOR MCU(+) FAN MOTOR 15.9 R407C COMPRESSOR (1 PHASE) NOMINAL FLA R407C COMPRESSOR (3 PHASE) NOMINAL FLA 15.2 R22 COMPRESSOR (1 PHASE) NOMINAL FLA R22 COMPRESSOR (3 PHASE) NOMINAL FLA MHPUE FAN MOTOR...
Page 8
HL/HLR Installation An envelope containing important user information is supplied with the indoor unit. Please pass this to the end user. Indoor Unit Cabinet Removal Press the filter tray at both sides to spring it and the filter out (Fig.1). Remove the two outer self tap screws then release the quarter turn fasteners.
Page 9
550 Series CONDENSING UNITS and 551 Series HEAT PUMP OUTDOOR UNITS INSTALLATION These outdoor units are for use in systems which use expansion devices. MCU = standard condensing unit MCU+ = standard condensing unit + FSC + LP MHPUE = electronic heat pump outdoor unit Some units are supplied with a number of loose restrictors which may be required, depending on the indoor unit it is matched with and whether the unit is to be run in NEMA conditions;...
Page 10
MOUNTING: MCU(+) 130 - 165 and MHPUE 100 - 130 MOUNTING HOLES All dimensions are in millimetres. MODEL Weight (kg) MCU(+) 130 1000 1020 1000 1020 MCU(+) 165 1000 1020 MHPUE 100 MHPUE 130 1000 1020 APPLICATION 1. To maximise performance, pipe runs should be kept as short as possible, avoiding sharp bends. However, individual pipe runs to a maximum of 80m, including 20m lift, are permissible provided good refrigeration practice is followed.
Page 11
MAXIMUM EQUIVALENT LENGTH OF EXPANSION SUCTION LINE LINES PIPES (M) UNIT 1-1/8 1-3/8 MCU(+) 90 MCU(+) 100 MCU(+) 130 MCU(+) 165 MHPUE 90 MHPUE 100 MHPUE 130 RESTRICTORS Outdoor units are supplied with cooling restrictors fitted in an expansion assembly; refer to the following tables for any restrictor changes: those ticked do not require changing.
Refrigeration Installation The refrigerant connections are terminated on the left hand side of the indoor coil and the lower front of the right end panel on outdoor units; (indoor units are brazed connections, outdoor units are flare fittings). Units are supplied with the following pipes: (HL are the same as HLR models; MCU+ are the same as MCU models). HLR 380 HLR 460 HLR 540 MCU 90 MCU 100 MCU 130 MCU 165 MHPUE 90 MHPUE 100 MHPUE 130 Expansion...
Page 14
In order to automatically switch off the fan in the event of a fire, it is necessary to fit an external switch (240V, 3A, closed to run, volt free contact) to:- HLR units: in the installer wire between terminal block terminal 2 and the Marstair remote control thermostat terminal 2(96000320) or L (97200211) HL units: in the internal (black) wire between the fuse and rotary switch terminal 'd'.
EVACUATING Connect a vacuum pump to the service ports on the outdoor unit valves and evacuate the interconnecting pipework and indoor unit to 1000 microns (1 Torr) or better and allow to be held for a minimum of 15 minutes. After evacuating the indoor unit and interconnecting pipework, open the outdoor unit valves using a 5mm Allen key.
Page 22
HL 460 to 540 + 3 Phase MCU(+) 130 to 165 HLR INTERCONNECTING WIRING DIAGRAMS HLR 380 + 1 Phase MCU(+) 90 HLR 380 to 460 + 3 Phase MCU(+) 90 to 100 -22-...
Page 23
HLR 380 + 1 Phase MHPUE 90 HLR 380 to 460 + 3 Phase MHPUE 90 to 100 HLR 460 to 540 + 3 Phase MCU(+) 130 to 165 HLR 540 + 3 Phase MHPUE 130 -23-...
Page 24
HL OPERATING INSTRUCTIONS (using Speed Selector Switch and Thermostat) The switches to operate the fan speed and thermostat control are located on the right hand side. The upper knob selects temperature, which is automatically controlled by an internal thermostat that senses return room air. Lower room temperatures can be maintained by turning the knob clockwise, further towards the snow flake.
FILTER. FAILURE TO DO SO WILL CAUSE A DECLINE IN UNIT PERFORMANCE AND MAY RESULT IN MALFUNCTION. We recommend that in order to prolong the life and maintain performance of your 'Marstair' units you arrange a regular service contract with your TEV Ltd. installer/dealer. -25-...
Page 26
CEILING MOUNTING KITS - 52600230 to 233 This kit converts HL (526) and HLR (527) indoor units for ceiling mounting. ITEM DESCRIPTION ITEM DESCRIPTION Ceiling Mounting Drip Tray No. 10 x 1/2" Screw Left Hand Sealing Plate Sensor Bracket Right Hand Sealing Plate Latch for Filter Carrier Ceiling mounted units can only have top discharge on the air off grille.
Page 27
CONDENSATE PUMP KIT 52600240 This kit is for use on all HL/HLR units for the removal of condensate where gravity drain is not practicable or desirable. The pump is capable of overcoming a resistance equivalent to 5 metres lift. The sensor is arranged so that residual condensate in the sump is kept to a minimum. The kit includes an overflow protection circuit which will prevent further cooling and condensate production if a high condensate level occurs.
Page 28
CEILING MOUNTED UNITS Remove the filter tray, release the fasteners and remove the cabinet, (Fig. 1). Locate and secure the pcb assembly in the left hand hanger bracket, (Fig. 4). Remove the rubber boots from the black and blue cables running across the front of the unit and connect to the pcb, black to L, blue to Cut the loop of the red cable (brown on HL units) running across the front of the unit, bare back by 5mm and connect to terminal TB1 on the...
Page 29
LOW PRESSURE HOT WATER COIL KIT This kit provides LPHW heating for HL (526) and HLR (527) indoor units. A control valve is not provided in this kit. Since the coil is upstream of the evaporator, a de-ice thermostat is not necessary on the LPHW coil. It is, however, highly recommended to fit a de-ice thermostat to the evaporator to protect the LPHW coil.
Page 30
EVAPORATOR DE-ICE THERMOSTAT KIT 52600242 This kit stops the compressor running during cooling mode if the indoor coil starts to ice up, (due to lack of charge, blocked filter or over condensing). This kit MUST be fitted to all HL/HLR units with LPHW coils fitted, to provide protection against the hot water system freezing. ITEM DESCRIPTION ITEM...
FAULT FINDING CONDITION POSSIBLE CAUSE ACTION No electric supply at socket or switched fuse Check fuse rating and replace if necessary. A Indoor fan motor will not run Check for loose electrical connections Unit wiring fault Check wiring and connections Fan motor capacitor defective Replace if faulty Fan motor defective...