Code
Items to adjust
200
Automatic adjustment of auto-toner
sensor (Fuser heater ON)
201
Correction of auto-toner sensor
(Fuser heater ON)
205
Developer bias DC output adjustment
206
Developer bias actual value
210
Main charger grid bias output adjust-
ment
211
Main charger grid bias actual value
221
Transfer transformer DC output ad-
justment/center value
242
Control status of the drum surface
potential sensor
268
Image quality control
Display of the exposure corrected value
269
Image quality control
Display of limiter flag
290
Enforced performing of Image quality
control
291
Image quality control
Control status display
AR-651/810 ERROR CODES AND SELF-DIAGNOSIS 2 - 22
Adjustment mode (05)
Accept-
Function Default
able
value
ALL
ALL
0~255
ALL
141
0~255
ALL
0~255
ALL
112
0~255
ALL
0~255
ALL
175
0~255
ALL
0
0~255
ALL
0
-255
~255
ALL
0
0~255
ALL
ALL
0
0~255
Contents
- As the value increases, the
sensor output increases
correspondingly.
- The value starts changing
approx. 2 minutes after this
adjustment was started and is
automatically set in the range of
2.45 to 2.55V.
(
Chapter 3.2.)
As the value increases by "1",
output from the transformer
increases correspondingly.
(
Chapter 3.5.)
The developer bias value at the
latest printing is displayed.
As the value increases by "1",
output from the transformer
increases correspondingly.
(
Chapter 3.5.)
The main charger grid bias value
at the latest printing is displayed.
The voltage for the transfer belt
power supply roller can be
adjusted but cannot be meas-
ured.
* When carrying out an adjustment,
close the front cover and be
careful not to touch the high-
voltage section.
Operation