McQuay MWM Service Manual page 55

Hide thumbs Also See for MWM:
Table of Contents

Advertisement

MCQUAY Service Guide Book
Wall Mounted F Heatpump Inverter-X Model
Model
MWMX 10/15FR
COOL/DRY
HEAT
/
(Green)
(Red)
ON
/
Board
VA2.0
STAND-
BY/FAN
TIMER
(Orange)
(Orange)
/
/
/
/
ON or OFF
Handset
G17 / SLM3
Error
Operation / Faulty
Code
Indication
(SLM3)
--
Cooling mode
--
Dry mode
Stand-by / Fan
--
mode
--
Heating mode
--
Auto mode
--
Defrost mode
Indoor temperature
E1
sensors contact
loose / short
Outdoor
E2
temperature sensor
contact loose / short
Communication
E3
error between
indoor and outdoor
Compressor
E4
overload protection
Gas leak /
E6
compressor
overheat
Inverter error / PFC
E7
error
Outdoor total
E8
current trip / DC
peak
Indoor fan feedback
E9
error
BLINKING
54
Diagnosis
Action
-
-
-
-
-
-
Check indoor coil sensor
connection / change indoor
coil sensor
Check outdoor coil sensor
connection / change
outdoor coil sensor
Check connection wires
between indoor and
outdoor
If running ampere highly
increase, change the
compressor
Check for leakage & repair
/ Top up refrigerant
Check supply voltage and
compressor phase
Check the input current
and discharge pressure
Check indoor fan motor /
fan motor wiring

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents