Operations To Be Performed During The Third/Fourth Phase Of Test Cycle - Electrolux with VS81 timer Service Manual

Washing machines and washer-dryers with timer
Table of Contents

Advertisement

6.1.3
Operations to be carried out during the third/fourth phases of the test cycle
→ Functional check
Knob position
Phase
nd
2
Select DELICATES
cycle (step 49)
Select 40°C if the
WM features a
temperature selector
Heating element switch-on
3
If a temperature
regulator is fitted, set
Skipping of phase
to 0°C
If temperature
regulator is not
featured, wait until
Skipping of phase
the water reaches
40°C
Drain from full
Then turn to step 49
4
(DRAIN)
Check for empty tub. 30
seconds after empty is
reached, rapid timer advance
(washer-dryers only)
2001.08 eb
Solenoid valve does not fill
level water fill
Fills beyond 2
Heating element does not switch
on
The phase is skipped after a few
seconds
Timer does not advance
Timer does not advance
Timer advances before the
temperature is reached
Drain pump inoperative
Drain pump blocked
Pressure switch does not switch,
the timer advances after the
maximum time of 3 minutes
The timer does not advance
→ Fault
→ Check with machine off
Timer contact
Solenoid interrupted/blocked
Wiring to solenoid valve
Solenoid valve blocked
nd
level
Pressure switch does not
switch/leaks
Heating element interrupted/earthed Heating element
Anti-boiling pressure switch faulty
Check closure of timer contact: G6.3-
G6.4
Check the NTC sensor (25 KΩ
approx. at room temperature)
If the wiring and the NTC sensor are
OK, check continuity of wiring and
replace the timer
Continuity of wiring to selector
Temperature selector faulty
NTC sensor incorrectly calibrated
Timer motor blocked
NTC sensor incorrectly calibrated
Winding faulty / Impeller slippage
Foreign bodies / Filter clogged
Pressure switch closed on "EMPTY" Pressure switch
Timer motor blocked / no power
supply
34
→ Component to be
repaired/replaced
Timer
Solenoid valve
Wiring / Connectors
Solenoid valve
nd
2
level pressure switch faulty
Anti-boiling pressure switch
Timer
NTC sensor
Wiring / Timer
Wiring / Connector
Selector
NTC temperature sensor
Timer
NTC temperature sensor
Drain pump
Clean pump/drain filter and repeat
the test
Timer
599 34 85-05

Advertisement

Table of Contents
loading