96
Full Name
Test Pattern
Mnemonic
SVM
Argument(s)
Mode
Description
Select test pattern
Notes
Full Name
Default User Set
Mnemonic
USD
Argument(s)
Set selector
Description
Select user set to load when camera is reset
Notes
Full Name
Load User Set
Mnemonic
USL
Argument(s)
Set selector
Description
Load user set
Notes
Full Name
Save User Set
Mnemonic
USS
Argument(s)
Set selector
Description
Save user set
Notes
Full Name
Temperature
Mnemonic
VT
Argument(s)
Description
Display internal temperature in degrees Celsius
Notes
03-032-20176-02
When a test pattern is selected all digital processing (e.g. flat field, gain) is
disabled – it is re-enabled when sensor video is selected
The settings include all those listed by the GCP command plus the user FPN
coefficients, and user PRNU coefficients
Loads and makes current all the settings listed by the GCP command plus the
user FPN coefficients, and user PRNU coefficients
Saves all the current settings listed by the GCP command plus the user FPN
coefficients, and user PRNU coefficients
Measured with an accuracy of ± 1.5 ºC.
Piranha4 4K and 2K Dual Line Monochrome CMOS Camera User's Manual
0. Sensor Video
1. Ramp
2. A5
3. Each_tap_fixed
4. All_1365
5. All_1
0.
Factory set
1-8. User sets
0.
Factory set
1-8. User sets
1 to 8