785ILN (NG) & 785ILP (LPG)
Installation and Owner's Manual
WARNING
!
A barrier designed to reduce the risk of burns from the hot viewing
glass is provided with this appliance and shall be installed
for the protection of children and other at-risk individuals.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury or loss of life.
Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light the appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fi re department.
Installation and service must be performed
by a qualifi ed installer, service agency or the
gas supplier.
4002263-09
©2013, Miles Industries Ltd.
L
EGEND
Direct Vent Gas Insert
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
Miles Industries Ltd.
www.valorfi replaces.com
G4
L e a v e t h i s m a n u a l
w i t h t h e a p p l i a n c e .
R e t a i n t h i s m a n u a l
f o r f u t u r e r e f e r e n c e .
Please read this manual
BEFORE installing and
operating this appliance.
This manual contains instructions to install the
ENGINE ONLY. A front is also REQUIRED to
complete this installation. A barrier screen is pro-
vided with the front. Refer to the manual sup-
plied with the front for installation.
This appliance may be installed in an
after-market permanently located,
manufactured (mobile) home where not
prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certifi ed kit is used.
This appliance is a domestic room-heating
appliance. It must not be used for any other
purposes such as drying clothes, etc.
This appliance is suitable for installation in a
bedroom or bed sitting room.
Ce guide est disponible en français sur demande.
Patent Pending
I N S TA L L E R
C O N S U M E R

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LEGEND G4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Miles Industries LEGEND G4

  • Page 1 Installation and service must be performed bedroom or bed sitting room. by a qualifi ed installer, service agency or the Ce guide est disponible en français sur demande. gas supplier. Miles Industries Ltd. www.valorfi replaces.com 4002263-09 ©2013, Miles Industries Ltd.
  • Page 2: Table Of Contents

    Ceramic Logs Installation ........ 28 The information contained in this installation manual is believed to be correct at the time of printing. Miles Industries Ltd. reserves the right to change or modify any information or speci- fi cations without notice. Miles Industries Ltd.
  • Page 3: Safety Precautions

    Safety Precautions READ and UNDERSTAND all instructions carefully This unit MUST be used with a vent system as before starting the installation. FAILURE TO FOLLOW described in this installation manual. NO OTHER vent these installation instructions may result in possible fi re system or components MAY BE USED.
  • Page 4: Safety And Your Fireplace

    Safety and Your Fireplace Safety and Your Fireplace Please Read and Carefully Follow all Safety Warnings and Operating Instructions Contained in Your Owners Manual (Replacement Manuals are available by contacting our service department at 1-800-468-2567 or visit www.valorfi replaces.com). withdraw in the event of accidental Please Follow These Important contact with a hot surface.
  • Page 5: Owner's Information

    Owner’s Information INFORMATION Thank You ... WARNING For purchasing a Valor by Miles Industries. Your new EXTREMELY HOT!!! radiant gas heater is a technical appliance that must be installed by a qualifi ed dealer. Each Valor fi replace • READ the SAFETY information on pages...
  • Page 6 3. Find the levers on each particular case. side of the window towards NOTE: This is a problem beyond Miles Industries’ the top. Using your fi nger, control and is not covered under warranty. pull the levers towards you •...
  • Page 7 OWNER’S Owner’s Information INFORMATION 3. Apply light hand pressure against the window frame The appliance area must always be kept clear and sides to bed-in the window seal. free from combustible materials, gasoline and other fl ammable vapors and liquids. 4.
  • Page 8 OWNER’S Owner’s Information INFORMATION 5. Replace the cover and screw in place. (including pilot) How to Turn Your Fireplace OFF 6. Reconnect the battery box. Familiarize yourself with each of these methods before 7. Put the battery box back in its position. operating your fi...
  • Page 9: Remote Control Operation

    OWNER’S Remote Control Operation INFORMATION NOTE: Before using the remote control system for IMPORTANT: BEFORE YOU BEGIN, please note that the fi rst time, the receiver and the handset must be on this system, the settings of time, temperature and synchronized.
  • Page 10 OWNER’S Remote Control Operation INFORMATION • Press and hold (small fl ame) MODES OF OPERATION button to decrease fl ame height or • Briefl y pressing the SET button to set the appliance at pilot fl ame. changes the mode of operation in •...
  • Page 11 OWNER’S Remote Control Operation INFORMATION • TO OPEN AND CLOSE DOUBLE BURNER - Nighttime Setback T E M P (785 fi replace models only) Temperature Mode (Appliance must be in standby mode; pilot NOTE: The rear part of the double burner cannot be ac- ignited) - The room temperature tivated manually: it can only function with the re- is measured and compared to the...
  • Page 12 OWNER’S Remote Control Operation INFORMATION SETTING THE “NIGHTTIME SETBACK” SETTING THE ON / OFF TEMPERATURES TEMPERATURE (moon), “ SETTING THE “DAYTIME” TEMPERATURE Default Settings: ” (OFF) T E M P (sun), 23ºC / 74ºF Default Settings: TEMP • Briefl y press SET button to scroll to •...
  • Page 13 OWNER’S Remote Control Operation INFORMATION SETTING P1 OFF TIME SETTING PROGRAM TIMERS • You can program two periods of time between 12:00 • Briefl y press SET button to scroll am and 11:50 pm in each 24-hour cycle. to TIMER (moon) while the •...
  • Page 14: Options

    OWNER’S Remote Control Operation INFORMATION Timer Programming Example (default temperatures shown) 4:00 p.m.— 6:00 a.m.— 8:00 a.m.— 10:00 p.m.— ☼ 6:00 a.m.— ☼ ☼ ☽ ☽ Start time Start time End time End time Start time ☼ ☼ ☽ ☽ Set temp 40˚F Set temp...
  • Page 15: Lighting Instructions

    OWNER’S Lighting Instructions INFORMATION FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING : If you do not follow these instructions exactly A. This appliance has a pilot which must be lighted by hand or by remote control. Follow these instructions exactly. To save gas, turn the pilot off when not using the appliance for a prolonged period of time.
  • Page 16: Specifi Cations

    10.5 Manifold Pressure (in w.c.) Conversion Kits 11.0 Minimum Supply The 785 Legend G4 is supplied as natural gas or Pressure (in w.c.) propane gas and is fi eld convertible between fuels. See 10.0 14.0 Maximum Supply instructions packaged with the conversion kit for further Pressure (in w.c.)
  • Page 17: Overview

    QUALIFIED Overview INSTALLER This appliance may ONLY be installed in an existing unaltered, functioning solid-fuel burning fi replace with a working fl ue and constructed of non-combustible material. DO NOT install into combustible construction. This appliance is NOT APPROVED for installation with a zero clearance kit. WARNING WARNING Chimney Terminal Cap...
  • Page 18: Dimensions

    QUALIFIED Dimensions INSTALLER 33” (838 mm) 24” (610 mm) 6’ (1.9 m) Fan power cord 3” (76 mm) Optional fan 3” 3” 15” (76 mm) (76 mm) (381 mm) 15” 4” Trim (381 mm) (102 mm) (sold separately) 10” Gas line approx. 24“ (610 mm) of flex protruding from (254 mm) sheet metal box...
  • Page 19: Clearances

    QUALIFIED Clearances INSTALLER WARNING WARNING Some materials or items, although safe, may discolor, shrink, warp, crack, peel, Some materials or items, although safe, may discolor, shrink, warp, crack, peel, and so on because of the heat produced by the fi replace. Avoid placing candles, and so on because of the heat produced by the fi...
  • Page 20: Venting

    QUALIFIED Venting INSTALLER Typical Vent Installation See list of approved venting accessories on page 36 of this manual. NOTE: Flexible co-linear vent pipes may only be installed into existing non-combustible solid-fuel burning fi replaces Terminal Cap and chimneys. Vent Location The vent terminal must be located through the roof.
  • Page 21: Installation Planning

    QUALIFIED Installation Planning INSTALLER Only qualifi ed licensed or trained personnel should install this appliance. Installer—READ THIS FIRST 13. Refi t window. 1. YOU NEED TO KNOW FROM THE HOMEOWNER what accessories (surround, 14. Reinstall the hot glass warning plate if it has been screen, fan/blower, etc.) will be installed with removed.
  • Page 22: Appliance Preparation

    QUALIFIED Existing Fireplace Preparation INSTALLER Gas Line Routing Combustible Mantels Plan the routing of the gas line before proceeding. Combustible mantel clearances must conform to those Utilize the existing hole for the gas line of the factory- required for the original solid-fuel fi replace into which built fi...
  • Page 23 QUALIFIED Appliance Preparation INSTALLER Window Removal The window is held in place by a spring-loaded lever on each side. 1. To remove the window, locate the levers on each side of the window towards the top. Using your fi nger, pull the lever towards you and unhook it from the window frame bracket.
  • Page 24 QUALIFIED Appliance Preparation INSTALLER Venting Installation IMPORTANT: This appliance’s venting system is room sealed and therefore, does not require room air to be used in the combustion process. 1. Rough-in two 3” diameter vent liners into the existing chimney system from the roof. Be careful not to tear or damage the liners in the process.
  • Page 25: Supply Gas Installation

    QUALIFIED Supply Gas Installation INSTALLER The gas supply inlet connection is a 1/2” NPT female. Pressure Test Points Gas shut-off valve supplied on the end of stainless The minimum supply pressure is given in the section steel fl exible connector. Flex connector is located on Specifi...
  • Page 26 QUALIFIED Supply Gas Installation INSTALLER Use common elbow and fi ttings (not Alternate Inlet Connection supplied) to redirect the position of In cases where local codes do not permit the fl ex the fl ex connector. NOTE: the fl ex connector to be used inside the appliance case, connector bend radius must be no reconnect the fl...
  • Page 27: Burner Removal And Reinstall

    QUALIFIED Burner Removal and Reinstall INSTALLER The ceramic panels can be installed without removing 2. Grab the burner as indicated and gently pull up the the burner. However, you can remove the burner for rear fi rst and then the front. Be careful not to hook additional space if desired.
  • Page 28: Ceramic Logs Installation

    QUALIFIED Ceramic Logs Installation INSTALLER Unpack the ceramic logs very carefully to avoid damaging them. Install the logs as shown below. Please note that the position of the logs is critical to insure proper performance of the appliance. When placing the base and middle logs, rotate them a little bit to anchor them into position. 1.
  • Page 29 QUALIFIED Ceramic Logs Installation INSTALLER 4. Place the center base log locating its notch on the key in the ember bed as indicated. The darkened part of this log should be on the left side. 5. Place the right-hand base log locating its notch on the key in the ember bed as indicated. 6.
  • Page 30: Ceramic Logs Installation

    QUALIFIED Ceramic Logs Installation INSTALLER 8. Place the right-hand cross log locating its notch on the key on the top of the rear log as indicated. Rest the front end of the log centered on top of the center base log. Ensure the logs do not cover the burner holes indicated here...
  • Page 31: Window Refi Tting

    QUALIFIED Window Refi tting INSTALLER 1. To refi t the window, place it in its bottom railing and rotate its top against the fi rebox. 2. While you hold it, pull the side levers back into the Window frame window brackets on each side. IMPORTANT: To ensure a safe operation, verify that the levers are hooked properly to the window tabs;...
  • Page 32: Remote Control Initial Set-Up

    QUALIFIED Remote Control Initial Set-up INSTALLER The receiver and the handset of the remote control 5. With a sharp object, press and hold the receiver’s system must be initially synchronized before the fi rst reset button until you hear one short and one long use.
  • Page 33: Operation Check & Aeration Settings Adjustment

    QUALIFIED Operation Check & Aeration Settings Adjustment INSTALLER In a few unusual installations, the fl ame picture may Operation Check be improved by adjusting the aeration. The need for Turn the fi replace fl ame up and down using the adjustment should be determined only by operating the remote control to confi...
  • Page 34: Side Shrouds Installation

    QUALIFIED Side Shrouds Installation INSTALLER The side shrouds are required to install the front on Door hinge tabs the appliance. They are supplied with the engine. should face inwards Fit them to the appliance outer case as indicated (2 screws/side). Front, Trim and Barrier Screen Installation Install the front or trim chosen by the customer for their Follow the instructions provided with the front or trim...
  • Page 35: Wiring Diagram

    QUALIFIED Wiring Diagram INSTALLER Latching Solenoid Valve Optional Wall Switch Kit 1265WSK Connector Yellow Optional Fan Remote 795CFK Battery Box Control Module 4 AA Batteries GV60 Wiring Diagram...
  • Page 36: Approved Venting Components

    QUALIFIED Approved Venting Components INSTALLER Approved Direct Vent Suppliers for Valor Models 700, 739, 780, 785 and RF24DV Venting Parts Code / availability by Manufacturer Venting Parts Description 4DVC Standard Co-axial 46DVA-VC 4DT-VC TM-4VT — HSDV4658-1313 — 4DH-1313 High Wind Co-axial 46DVA-VCH —...
  • Page 37: Warranty

    1. Extended Warranty Coverage For a period of up to ten (10) years, Miles Industries Ltd., (the “Company”) or its appointed distributor will at its option pay the initial purchaser for the repair of, or will exchange the following parts or components which are found to be defective in material or...
  • Page 38: Spare Parts

    OWNER’S Spare Parts INFORMATION Part Part Code Description Code Description Number Number Exhaust Slide Assembly 4002287 Injector nut 420K464 Exhaust Slide Gasket 4000176 Air shutters (2) 4002590 Restrictor enclosure 4002330 Front - Injector elbow #500 NG 4002606 Metal strip 4002329 Front - Injector elbow #150 LPG 4002867 Restrictor assembly...
  • Page 39 OWNER’S Spare Parts INFORMATION Part Code Description Number Left side panel Ledgestone 4002365 Enamel black 4002371EB Ceramic fl uted black 4002377 Valor red brick 4002382 Right side panel Ledgestone 4002366 Enamel black 4002372EB Ceramic fl uted black 4002378 Valor red brick 4002383 Hot glass warning plate 4003093...
  • Page 40 OWNER’S Spare Parts INFORMATION 3–7 27a, 27b 32 – 38...
  • Page 41: Miles Industries Ltd

    Serial Number: Date Purchase (yyyy-mm-dd): Dealer: Customer Information First Name: Last Name: Contact Information Email: Mailing Address Address: City: Province/State: Postal/Zip Code: Country: Cut out page, fi ll information, and mail to Miles Industries Ltd. Online Warranty registration at www.valorfi replaces.com...