Miles Industries H4 Installation & Owner's Manual

H4 series dv gas fireplace heater

Advertisement

Quick Links

650ILN/ILP (Logs) & 650IRN/IRP (Rocks)
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury or loss of life.
Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light the appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fi re department.
Installation and service must be performed
by a qualifi ed installer, service agency or the
gas supplier.
4001955-19
© 2012, Miles Industries Ltd. All rights reserved.
H4 S
DV Gas Fireplace Heater
Installation & Owner's Manual
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
Manufactured by
MILES INDUSTRIES LTD., British Columbia, Canada
www.valorfi replaces.com
ERIES
Leav e t his manua l
with the applia nce .
Ret ain this ma nual
for f uture r efe re nce.
Please read this manual BEFORE installing
and operating this appliance.
This appliance may be installed in an
after-market permanently located,
manufactured (mobile) home where not
prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certifi ed kit is used.
This appliance is a domestic room-heating
appliance. It must not be used for any other
purposes such as drying clothes, etc.
This appliance is suitable for installation in a
bedroom or bed sitting room.
Massachusetts: The piping and fi nal
gas connection must be performed by a
licensed plumber or gas fi tter in the State of
Massachusetts. Also, see Carbon Monoxide
Detector requirements on page 16.
Ce guide est disponible en français sur demande.
IN STA LLER
C ON SU MER

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Miles Industries H4

  • Page 1 Massachusetts. Also, see Carbon Monoxide gas supplier. Detector requirements on page 16. Ce guide est disponible en français sur demande. Manufactured by MILES INDUSTRIES LTD., British Columbia, Canada www.valorfi replaces.com 4001955-19 © 2012, Miles Industries Ltd. All rights reserved.
  • Page 2: Table Of Contents

    Replacement Parts .......... 46 The information contained in this installation manual is believed to be correct at the time of printing. Miles Industries Ltd. reserves the right to change or modify any information or specifi ca- tions without notice. Miles Industries Ltd. grants...
  • Page 3: Safety Precautions

    Safety Precautions READ and UNDERSTAND all instructions carefully This unit MUST be used with a vent system as before starting the installation. FAILURE TO FOLLOW described in this installation manual. NO OTHER vent these installation instructions may result in possible fi re system or components MAY BE USED.
  • Page 4: Safety And Your Fireplace

    Safety and Your Fireplace Safety and Your Fireplace Please Read and Carefully Follow all Safety Warnings and Operating Instructions Contained in Your Owners Manual (Replacement Manuals are available by contacting our service department at 1-800-468-2567 or visit www.valorfi replaces.com). withdraw in the event of accidental Please Follow These Important contact with a hot surface.
  • Page 5: Owner's Information

    Owner’s Information INFORMATION Thank You ... WARNING For purchasing a Valor by Miles Industries. Your new EXTREMELY HOT!!! radiant gas heater is a technical appliance that must be installed by a qualifi ed dealer. Each Valor fi replace • READ the SAFETY information on pages...
  • Page 6 2. Refi t the top two bolts securing by turning them through 90 degrees. NOTE: This is a problem beyond Miles Industries’ 3. Hook the window baffl e to the top of the window control and is not covered under warranty.
  • Page 7 OWNER’S Owner’s Information INFORMATION 7. If the Hot Glass Warning plate has been removed Rock fuel bed from the front lower corner of the window, A black discoloration may form over time at the front reinstall it by sliding it between the glass and bottom of the 6-rock original fuel bed;...
  • Page 8 OWNER’S Owner’s Information INFORMATION 2. Slide and remove the receiver cover. How to Turn Your Fireplace OFF (including pilot) 3. Replace the 4 AA batteries. 4. Replace the cover. Familiarize yourself with each of these methods before 5. Put the receiver back in its position pushing it in so it operating your fi...
  • Page 9: Remote Control Operation

    OWNER’S Remote Control Operation INFORMATION NOTE: Before using the remote control system for IMPORTANT: BEFORE YOU BEGIN, please note that the fi rst time, the receiver and the handset must be on this system, the settings of time, temperature and synchronized.
  • Page 10 OWNER’S Remote Control Operation INFORMATION • Press and hold (small fl ame) MODES OF OPERATION button to decrease fl ame height or • Briefl y pressing the SET button to set the appliance at pilot fl ame. changes the mode of operation in •...
  • Page 11 OWNER’S Remote Control Operation INFORMATION SETTING THE ON / OFF TEMPERATURES SETTING THE “NIGHTTIME SETBACK” TEMPERA- SETTING THE “DAYTIME” TEMPERATURE TURE (moon), “ Default Settings: 23ºC / 74ºF Default Settings: ” (OFF) TEMP T E M P • Briefl y press SET button to scroll to •...
  • Page 12 OWNER’S Remote Control Operation INFORMATION SETTING PROGRAM TIMERS SETTING P1 OFF TIME • You can program two periods of time between 12:00 • Briefl y press SET button to scroll am and 11:50 pm in each 24-hour cycle. to TIMER (moon) while the •...
  • Page 13: Wall Switch Operation

    OWNER’S Remote Control Operation INFORMATION Timer Programming Example (default temperatures shown) 4:00 p.m.— 6:00 a.m.— 8:00 a.m.— 10:00 p.m.— ☼ ☼ 6:00 a.m.— ☼ ☽ ☽ Start time Start time End time End time Start time ☼ ☼ ☽ ☽ Set temp 40˚F Set temp...
  • Page 14: Options

    OWNER’S Options INFORMATION 755CFK—Circulating Fan Kit Required Kits Having variable speed and temperature control, it is Liners (choose one) designed to boost the natural convection process through 618EBL—Enamel Black Liner (Steel) the appliance. It may be fi tted before the fi replace is 620FBL—Fluted Black Liner (Ceramic) installed or retrofi...
  • Page 15: Lighting Instructions

    OWNER’S Lighting Instructions INFORMATION FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand, remote control, or wall switch. Follow these instructions exactly.
  • Page 16: Commonwealth Of Massachusetts

    QUALIFIED Commonwealth of Massachusetts INSTALLER 3. SIGNAGE. A metal or plastic identifi cation plate State of Massachusetts Carbon Monoxide shall be permanently mounted to the exterior of the Detector/Vent Terminal Signage building at a minimum height of eight (8) feet above Requirements grade directly in line with the exhaust vent terminal for For all side wall horizontally vented gas fueled...
  • Page 17 QUALIFIED Commonwealth of Massachusetts INSTALLER (d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the fl ue gases, but identifi...
  • Page 18: Specifi Cations

    QUALIFIED Specifi cations INSTALLER Approvals & codes Supply Gas These appliances are certifi ed by ANSI Z21.88-2009/CSA Heater engine units 650ILN/IRN are used with natural gas 2.33-2009 American National Standard / CSA Standard installations. for Vented Gas Fireplace Heaters for use in Canada and Heater engine units 650ILP/IRP are used with propane USA.
  • Page 19: Overview

    QUALIFIED Overview INSTALLER Framing—See Framing section Field convertible Remote Handset Wall Holder from top to rear outlet Min. 3/4” (19 mm) Fire On/Off Wall Switch 650IL or (supplied, required) 650IR Combustible framing allowed beneath Wall Finish fi replace. When May be combustible material. the appliance is NOTE: Finished wall surface, installed directly on...
  • Page 20: Dimensions

    QUALIFIED Dimensions INSTALLER 8-1/4” (210 mm) From finished wall surface to top vent MINIMUM 3/4” (19 mm) from finished Stand-off wall surface to front of 3” (76 mm) min. appliance To side wall from inner frame in front of the appliance See table 36”...
  • Page 21: Framing

    QUALIFIED Framing INSTALLER • A non-combustible hearth is not necessary in front of this appliance. • Note that the unit is installed at the framing stage and fi xed to framing using support angles. See page 31. The wall fi nish is then installed over the support angles up to the front frame on the unit, on the sides and up to the stand-offs on the top.
  • Page 22: Location

    QUALIFIED Location INSTALLER Venting Vent Material Vent Penetration through Walls & Ceilings This unit is approved for installation using 4 by 6-5/8 Combustible: When penetrating through combustible inches diameter approved co-axial direct vent pipes walls and ceilings, frame a minimum of 10 inch by and accessories listed on pages 43–44 of this guide.
  • Page 23: Co-Axial Venting

    QUALIFIED Co-Axial Venting INSTALLER Typical Co-Axial Venting Components VERTICAL TERMINATION STORM COLLAR FLASHING ATTIC INSULATION SHIELD ATTIC FIRESTOP CEILING FIRESTOP HORIZONTAL 2-PIECE TERMINATION 90˚ ELBOW PIPE WALL PIPE LENGTH THIMBLE LENGTH PIPE LENGTH PIPE LENGTH 817VAK 817VAK...
  • Page 24 QUALIFIED Co-Axial Venting INSTALLER Co-Axial Venting Rear Vent with No Vertical Rise The horizontal vent run cannot be extended by the use of any vent accessory pipes. Vent pipe max. 15” (381 mm) 26” (660 mm) max. after 45° elbow vent length (14”...
  • Page 25 QUALIFIED Co-Axial Venting INSTALLER Horizontal Vent Termination Location • The vent terminal must be located on an outside wall or through the roof. • This direct vent appliance is designed to operate when an undisturbed airfl ow hits the outside vent terminal from any direction.
  • Page 26 QUALIFIED Co-Axial Venting INSTALLER Co-Axial Venting Confi gurations with Vertical Rise 4 x 90º ELBOWS MAXIMUM (or equivalent) 3” min. above top of horizontal pipe 1” min. all around vertical pipe 1” min. around bottom & sides of horizontal pipe Min.
  • Page 27 QUALIFIED Co-Axial Venting INSTALLER 5. Each 90 degrees elbow installed on the horizontal How to Read the Venting Chart plane is equivalent to a 3 feet horizontal pipe; The chart below applies to co-axial roof or wall therefore, 3 feet must be subtracted from allowable termination in installations with vertical rise.
  • Page 28 QUALIFIED Co-Axial Venting INSTALLER Co-Axial Vertical Installations Overhang should • Check the roof pitch to determine which roof not extend beyond vent if within 48” of fl ashing will be needed. See venting accessories list Horizontal termination cap on pages 43–44 for allowable components. overhang •...
  • Page 29: Co-Linear Venting

    QUALIFIED Co-Linear Venting INSTALLER Co-Linear Vent Installations Approved co-linear termination or approved • The fi replace dimensions are shown in the co-linear adapter 3” min. and approved 2 x 3” Dimensions section of this manual. bend radius Flashing co-axial liners termination •...
  • Page 30: Appliance Preparation

    QUALIFIED Appliance Preparation INSTALLER Window Removal 1. Turn the top two spring-loaded window bolts through 90 degrees to release the window from the fi rebox. 2. Remove the bottom two spring-loaded window bolts. 3. Carefully lift the window away. Keep the window and bolts in a safe place. Rear Vent Outlet Positioning If installing with top vent outlet, ignore this stage.
  • Page 31: Appliance Preparation

    QUALIFIED Appliance Preparation INSTALLER Stand-off and Support Angles Installation Thickness of wall finish + extra 3/4” (19 mm) and Fitting (Appliance MUST project 3/4” (19 mm) in front of the wall finish surface) The distance from the support angles to the front face Fix to appliance of the heater case is adjustable to allow for a range of case with...
  • Page 32 QUALIFIED Appliance Preparation INSTALLER Air Restrictors Fitting No restrictors are required for appliances which only have a horizontal vent run. If installing an appliance which has a rear vent outlet connection and no vertical vent pipe rise, ignore this stage. Two restrictor sets, like the one shown at right, are supplied with each 650 engine unit.
  • Page 33: Gas Supply Installation

    QUALIFIED Gas Supply Installation INSTALLER » • The gas supply pipe should enter the appliance The appliance must be isolated from the case through the opening at the left side. The supply gas supply piping system by closing its pipe should be connected to the appliance gas inlet individual manual shut-off valve during any pipe situated at the left side of the control valve.
  • Page 34: Liner Panels Installation

    QUALIFIED Liner Panels Installation INSTALLER All liner panels can be installed as indicated below. 4. Insert the top panel over the left side panel while Unpack the liners carefully to avoid scratching or holding the top panel forward up the slope. Rotate damaging them.
  • Page 35: Ceramic Logs Installation (650Il)

    QUALIFIED Ceramic Logs Installation (650IL) INSTALLER Unpack the ceramic logs very carefully to avoid damaging their fragile material. Install the logs as shown below. Please note that the position of the logs is critical to insure the good performance of the appliance. 1.
  • Page 36: Ceramic Rocks Installation (650Ir)

    QUALIFIED Ceramic Rocks Installation (650IR) INSTALLER Unpack the ceramic rocks kit very carefully to avoid damaging the fragile material. Install the components as shown below. Please note that the position of the rocks and twigs (if used) is critical to ensure proper performance of the appliance.
  • Page 37 QUALIFIED Ceramic Rocks installation (650IR) INSTALLER 4. The underside of each ceramic rock is identi- fi ed by a number and a specifi c protruding positioning triangle. Rock identifi cation Install the six rocks from left to right starting with rock no. 1. Triangular hole in ceramic...
  • Page 38: Window Refi Tting & Baffl E Installation

    QUALIFIED Window Refi tting & Baffl e Installation INSTALLER 1. Slide the window inside the appliance case and rest 4. Grab the top of the window and baffl e and pull them it on the fi rebox front bottom tabs. Refi t the bottom forward and release to check that the window opens two bolts.
  • Page 39: Wall Switch Kit Installation (Required)

    QUALIFIED Wall Switch Kit Installation (required) INSTALLER 3. Pull out the receiver box. Remove the batteries from WARNING the receiver box if it contains any. You can remove the ignition wire to improve access to the receiver. FOR S A FE TY PU R P OS E, t he wa ll s witc h F OR SAF ET Y PUR P OS E, t he wa ll s w i tc h 4.
  • Page 40: Remote Control Initial Set-Up

    QUALIFIED Remote Control Initial Set-up INSTALLER The receiver and the handset of the remote control system must be initially synchronized before the fi rst use. 1. Insert alkaline batteries in the remote control receiver and handset. The receiver is located left of the control valve under the burner module.
  • Page 41: Remote Control Handset Wall Holder Installation

    QUALIFIED Remote Control Handset Wall Holder Installation INSTALLER The remote control kit for this fi replace comes complete with a wall-mounted holder. This Alternative 2 Packing Contents: Alternative 3 holder is not required in all installations but 1 Wall Bracket A is provided as an optional feature for those 2 Screws B 1 Screw C...
  • Page 42: Wiring Diagram

    QUALIFIED Wiring Diagram INSTALLER Wall Switch Kit Connector GV60 Wiring Diagram...
  • Page 43: Approved Venting Components

    QUALIFIED Approved Venting Components INSTALLER Approved Direct Vent Suppliers for Valor Models 530, 534, 535, 650, and MF28 Venting Parts Code / availability by Manufacturer Venting Parts Description Co-axial Kit, 26” long — — — — — — 551DVK Standard Co-axial 46DVA-HC 4DT-HC TM-4HT...
  • Page 44 QUALIFIED Approved Venting Components INSTALLER Venting Parts Code / availability by Manufacturer Venting Parts Description Galvanized 46DVA-06 4DT-06 TC-4DL6 SV4L6 6” long — — — Black 46DVA-06B 4DT-06(B) TC-4DL6B SV4LB6 Galvanized 7” long — — — — — — Black 4D7B Galvanized 46DVA-09...
  • Page 45: Warranty

    1. Extended Warranty Coverage For a period of up to ten (10) years, Miles Industries Ltd., (the “Company”) or its appointed distributor will at its option pay the initial purchaser for the repair of, or will exchange the following parts or components which are found to be defective in material or...
  • Page 46: Replacement Parts

    OWNER’S Replacement Parts INFORMATION Key Description Part no. Key Description Part no. Outer vent collar 330A888 GV60 Valve assembly NG 4003095 Blanking plate 330A964 GV60 Valve assembly LPG 4003108 Side frame fi xing brackets (2) 3000255 Ignition cable 500 mm 4001039 Rear log support 4001999...
  • Page 47 OWNER’S Replacement Parts INFORMATION Key Description Part no. Rock No. 1 4001821 Rock No. 2 4001822 Rock No. 3 4001823 Rock No. 4 4001824 Rock No. 5 4001825 Rock No. 6 4001826 Rock Base 4001792 LH Twig 4001827 RH Twig 4001828 Front Support—Platform 4001998AH...
  • Page 48 OWNER’S INFORMATION 40a, 40b...
  • Page 49: Miles Industries Ltd

    Serial Number: Date Purchase (yyyy-mm-dd): Dealer: Customer Information First Name: Last Name: Contact Information Email: Mailing Address Address: City: Province/State: Postal/Zip Code: Country: Cut out page, fi ll information, and mail to Miles Industries Ltd. Online Warranty registration at www.valorfi replaces.com...
  • Page 50: Miles Industries Ltd

    Tape Shut Fold here Postage needed Miles Industries Ltd. 190 - 2255 Dollarton Highway North Vancouver, BC V7H 3B1 Canada Online Warranty registration at www.valorfi replaces.com Thank you for choosing a Valor Product...

This manual is also suitable for:

650iln650ilp650irn650irp

Table of Contents