Miles Industries L2 SERIES Owner's Manual

Dv zc gas fireplace 1700in (ng) & 1700ip (lpg)

Advertisement

Quick Links

1700IN (NG) & 1700IP (LPG)
DANGER
!
A barrier designed to reduce the risk of burns from the hot
viewing glass is provided with this appliance and shall be
installed for the protection of children and other at-risk
individuals.
!
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
— Do not store or use gasoline or other
fl ammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
▪ Do not try to light any appliance.
▪ Do not touch any electrical switch; do
not use any phone in your building.
▪ Leave the building immediately.
▪ Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
▪ If you cannot reach your gas supplier,
call the fi re department.
— Installation and service must be
performed by a qualifi ed installer, service
agency or the gas supplier.
4003743-07
©2014, Miles Industries Ltd.
L2 S
DV ZC Gas Fireplace
Installation & Owner's Manual
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
ERIES
Please read this manual
BEFORE installing and
operating this appliance.
This manual contains instructions to install the
ENGINE ONLY. A front or trim kit is REQUIRED
to install the engine. A barrier screen is provided
with the front or trim kit. Refer to the manual
supplied with the front or trim for installation.
This appliance may be installed in an
after-market permanently located,
manufactured (mobile) home where not
prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certifi ed kit is used.
This appliance is a domestic room-heating
appliance. It must not be used for any other
purposes such as drying clothes, etc.
This appliance is suitable for installation in a
bedroom or bed sitting room.
Ce guide est disponible en français sur demande.
I N S TA L L E R
L e a v e t h i s m a n u a l
w i t h t h e a p p l i a n c e .
C O N S U M E R
R e t a i n t h i s m a n u a l
f o r f u t u r e r e f e r e n c e .

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the L2 SERIES and is the answer not in the manual?

Questions and answers

Summary of Contents for Miles Industries L2 SERIES

  • Page 1 fi re department. bedroom or bed sitting room. — Installation and service must be Ce guide est disponible en français sur demande. performed by a qualifi ed installer, service agency or the gas supplier. 4003743-07 ©2014, Miles Industries Ltd.
  • Page 2: Table Of Contents

    fi tter in the State of North Vancouver, BC, CANADA V7H 3B1 Massachusetts. Also, see Carbon Monoxide Tel. 604-984-3496 Fax 604-984-0246 Detector requirements on page 17. www.valorfi replaces.com © Copyright Miles Industries Ltd., 2014. All rights reserved.
  • Page 3: Safety Precautions

    Safety Precautions READ and UNDERSTAND all instructions carefully Due to the high temperature, the appliance should be before starting the installation. FAILURE TO FOLLOW LOCATED out of traffi c areas and away from furniture these installation instructions may result in possible fi re and draperies.
  • Page 4: Safety And Your Fireplace

    Safety and Your Fireplace Safety and Your Fireplace Please Read and Carefully Follow all Safety Warnings and Operating Instructions Contained in Your Owner’s Manual (Replacement Manuals are available by contacting our service department at 1-800-468-2567 or visit www.valorfi replaces.com). withdraw in the event of accidental Please Follow These Important contact with a hot surface.
  • Page 5: Owner's Information

    Owner’s Information INFORMATION Thank You ... WARNING For purchasing a Valor by Miles Industries. Your new EXTREMELY HOT!!! radiant gas heater is a technical appliance that must be installed by a qualifi ed dealer. Each Valor fi replace • READ the SAFETY information on pages...
  • Page 6: Cleaning Your Fireplace

    Dealers have tried various cleaning products with varying results. The following are recommendations only and are not meant to guarantee results. NOTE: This is a problem beyond Miles Industries’ 1755 1” Trim 1750 5.1/4” and 1770 Trims control and is not covered under warranty.
  • Page 7: Checking Pilot And Burner Flames

    OWNER’S Owner’s Information INFORMATION applied to the surface, no alcohol/solvent based clean- 5. Reinstall the barrier screen on the trim. ing agents nor polishes should be used. Dry stains can WARNING be removed using a white or light colored cloth with mild soap and warm water when the material is cool, then FOR SAFETY PURPOSE, ensure the barrier dried immediately.
  • Page 8: Replacing Batteries

    OWNER’S Owner’s Information INFORMATION The appliance area must always be kept clear and 2. Slide battery carrier to ease access. free from combustible materials, gasoline and other battery box fl ammable vapors and liquids. Inspect the vent terminal outdoors regularly to make sure that snow, trees, bushes, leaves, or other objects do not obstruct it.
  • Page 9: Using Remote Control Handset Wall Holder

    OWNER’S Owner’s Information INFORMATION How to Turn Your Fireplace OFF (including pilot) Data Familiarize yourself with each of these methods before plate operating your fi replace. Window Press and hold the OFF button for a second (either on the handset or the wall switch). If the fl...
  • Page 10: Remote Control Operation

    OWNER’S Remote Control Operation INFORMATION NOTE: Before using the remote control system for IMPORTANT: BEFORE YOU BEGIN, please note that the fi rst time, the receiver and the handset must be on this system, the settings of time, temperature and synchronized.
  • Page 11 OWNER’S Remote Control Operation INFORMATION MODES OF OPERATION • Press and hold (small fl ame) button to decrease fl ame height or • Briefl y pressing the SET button to set the appliance at pilot fl ame. changes the mode of operation in •...
  • Page 12 OWNER’S Remote Control Operation INFORMATION SETTING THE ON / OFF TEMPERATURES SETTING THE “NIGHTTIME SETBACK” SETTING THE “DAYTIME” TEMPERATURE TEMPERATURE Default Settings: (sun), 23ºC / 74ºF Default Settings: (moon), “ ” (OFF) TEMP T E M P • Briefl y press SET button to scroll to •...
  • Page 13 OWNER’S Remote Control Operation INFORMATION SETTING PROGRAM TIMERS SETTING P1 OFF TIME • You can program two periods of time between 12:00 • Briefl y press SET button to scroll am and 11:50 pm in each 24-hour cycle. to TIMER (moon) while the •...
  • Page 14 OWNER’S Remote Control Operation INFORMATION Timer Programming Example (default temperatures shown) 4:00 p.m.— 6:00 a.m.— 8:00 a.m.— 10:00 p.m.— ☼ 6:00 a.m.— ☼ ☼ ☽ ☽ Start time Start time End time End time Start time ☼ ☼ ☽ ☽ Set temp 40˚F Set temp...
  • Page 15: Wall Switch Operation

    OWNER’S Wall Switch Operation INFORMATION The Wall Switch can be used to TO ADJUST FLAME HEIGHT control your fi replace. You can turn the pilot on or off and you can • Press and hold large fl ame increase or decrease the fl ame button to gradually increase height.
  • Page 16: Lighting Instructions

    OWNER’S Lighting Instructions INFORMATION FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand, remote control, or wall switch. Follow these instructions exactly.
  • Page 17: Commonwealth Of Massachusetts

    QUALIFIED Commonwealth of Massachusetts INSTALLER State of Massachusetts Carbon Monoxide 3. SIGNAGE. A metal or plastic identifi cation plate shall be permanently mounted to the exterior of the Detector/Vent Terminal Signage building at a minimum height of eight (8) feet above Requirements grade directly in line with the exhaust vent terminal for For all side wall horizontally vented gas fueled...
  • Page 18 QUALIFIED Commonwealth of Massachusetts INSTALLER (d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the fl ue gases, but identifi...
  • Page 19: Specifi Cations

    QUALIFIED Specifi cations INSTALLER Approval & Codes For installations at elevations above 4,500 feet (1,370 m) in Canada, please consult provincial and/or This appliance is certifi ed to ANSI Z21.88-2014/ local authorities having jurisdiction. CSA 2.33-2014 American National Standard / CSA Standard for Vented Gas Fireplace Heaters for use in Supply Gas Canada and USA, and to CGA 2.17-91 High Altitude...
  • Page 20: Overview

    QUALIFIED Overview INSTALLER Fire On/Off Wall Switch Mantel—See Mantel & Hearth Clearances (20-foot wire length) (supplied, recommended) Framing—See Framing Requirements Remote Handset Supplied as Wall Holder vertical outlet, fi eld 1/2 inch thick Optional Decorative convertible to S urrou non-combustible Light Dimmer horizontal outlet.
  • Page 21: Dimensions & Location

    QUALIFIED Dimensions & Location INSTALLER Dimensions 57.3/4” (1467 mm) 52” (1321 mm) Center Line Heat shield required for rear vent outlet 18-5/8” applications (473 mm) 15-3/16” Top View 6-5/8” dia. (386 6 mm) Venting field- convertible from top to Zero Clearance Header rear outlet Stand-Offs...
  • Page 22: Mantel & Hearth Clearances

    QUALIFIED Mantel & Hearth Clearances INSTALLER Combustible Mantel—Left Side View Ceiling Mantel Projection (from Face of Cement Board) 0 2” 4” 6” 8” 10” 12” 44” Mantel 42” Height (from 40” Bottom 38” of Unit) Face of 1/2” thick non-combustible cement board 23-7/8”...
  • Page 23 QUALIFIED Mantel & Hearth Clearances INSTALLER Combustible Sidewall / Mantel Leg—Top View FIREPLACE Face of Finished Wall Fireplace Opening 49-11/16” Wall Min. 4” to wall or combustible mantel leg...
  • Page 24: Framing Requirements

    QUALIFIED Framing Requirements INSTALLER Framing Dimensions NOTE: Height of cavity may be affected by vent configuration - see page 26 1/2” thick non-combustible cement board required above, on each side and below Between underside engine opening (NOT supplied) of header and bottom of firebox NOTE: This unit requires a solid platform to support it.
  • Page 25 QUALIFIED Framing Requirements INSTALLER Framing with Partial Shelf—Top Outlet 15-3/16” (386 mm) Approx. 10-3/4” (274 mm) from back surface of wall finish to front surface of appliance case w/no vent offset 1/2” thick Min. 1” non-combustible (25.4 mm) Cement Board clearance to combustibles around...
  • Page 26 QUALIFIED Framing Requirements INSTALLER Venting Considerations—Vertical Takeoff Notes—ALL venting considerations • Dimensions of venting are based on using Dura-Vent elbows. Elbow curve radius dimensions will vary when using 12” pipe section other brands. In general, other brands have slightly bigger radius. •...
  • Page 27: Venting

    QUALIFIED Venting INSTALLER Top or Rear Outlet Framing Vent in Combustible Walls & Ceilings This unit is supplied with a top vent outlet which can be fi eld-converted to a rear vent outlet. See Appliance When penetrating through combustible walls and Preparation section for more information.
  • Page 28: Co-Axial Venting

    QUALIFIED Co-axial Venting INSTALLER Typical Co-axial Venting Components HORIZONTAL TERMINATION 2-PIECE WALL THIMBLE VERTICAL TERMINATION 90˚ ELBOW PIPE STORM LENGTH COLLAR PIPE LENGTH FLASHING 90˚ ELBOW ATTIC INSULATION SHIELD HORIZONTAL TERMINATION ATTIC FIRESTOP CEILING FIRESTOP 2-PIECE Rear Vent WALL THIMBLE PIPE LENGTH PIPE LENGTH...
  • Page 29 QUALIFIED Co-axial Venting INSTALLER How to Read the Venting Chart be used. Excludes the 45 degrees take-off elbow shipped with the appliance. The chart below applies to co-axial roof or wall 6. Each 90 degrees elbow installed on the horizontal termination.
  • Page 30 QUALIFIED Co-axial Venting INSTALLER Restrictor The restrictor is located in the roof of the fi rebox hidden above the top liner panel. Adjust the restrictor before installation of the top liner panel. Should subsequent adjustment be required, you will need to remove the top liner panel—see page 41.
  • Page 31: Vent Termination

    QUALIFIED Co-axial Venting INSTALLER Vent Termination • The vent terminal must be located on an outside of the airfl ow or a safety hazard. Local codes or wall or through the roof. regulations may require greater clearances. • This direct vent appliance is designed to operate •...
  • Page 32: Co-Linear Venting

    QUALIFIED Co-axial Venting INSTALLER Vertical Vent Termination Overhang should not extend beyond vent if within 48” of Horizontal termination cap Roof Minimum overhang Pitch "H" (feet) Flat to 7/12 Termination Min. 24” Over 7/12 to (unvented soffit) 1.5' 8/12 Min. 36” Vertical Min.
  • Page 33 QUALIFIED Co-linear Venting INSTALLER 1156CLA Co-Linear Vent Adapter 8-5/8” FRONT REAR 52” 11-11/16” 9-3/8” 3” exhaust collar 4” exhaust collar 3” intake on the centerline 4” 32-3/8” 1-1/2” 4” exhaust collar adapter Dimensions with co-linear adapter Dimensions shown are with Valor 1156CLA co-linear adapter.
  • Page 34: Installation Planning

    QUALIFIED Installation Planning INSTALLER Installer—READ THIS FIRST Only qualifi ed licensed or trained personnel 8. Position the restrictor. should install this appliance. 9. Connect the electrical wiring for optional electric accessories if used. 1. YOU NEED TO KNOW FROM THE 10.
  • Page 35: Convert From Top To Rear Outlet (If Required)

    QUALIFIED Installation INSTALLER 3. Taking great care not to 2. Swivel the collar and install as a rear outlet (6 screws). cut your hands on the Reinstall heat sheet metal edges, lift the shield to top of appliance out of its packing appliance base and place it in the (3 screws)
  • Page 36: Plan Wall Finish

    QUALIFIED Installation INSTALLER Plan Wall Finish Non-combustible cement board Gypsum board The L2 Linear fi replace requires a 1/2” Min. 60” up to perimeter (13 mm) thick non-combustible cement (1524 mm) of cement board board to be used as a wall surface 50”...
  • Page 37: Remove Window

    QUALIFIED Installation INSTALLER Cracking • Always pre-drill screw holes through cement board and use screws with self-milling head. If a clean fi nish with no tile, etc. is desired, joints in • Always use tape over joints. the cement board and the transition to gypsum board will require special attention if future cracking is to be •...
  • Page 38: Install Electrical Wiring (For Optional Accessories)

    QUALIFIED Installation INSTALLER Install Electrical Wiring (for optional 2. Provide a steel surface mount electrical utility box (Iberville BC 1110 or equivalent), thread cable accessories) through knock-out in the end of box and through the This section provides information to install the electric cable clamp locking ring (if used).
  • Page 39: Set-Up Gas Supply

    QUALIFIED Installation INSTALLER 7. Pull the excess cable back through the cable clamp and tighten the locking ring to the cable clamp. Alternate clamp without locking ring may be used - ensure the proper clamp is used for the type of cable used.
  • Page 40 QUALIFIED Installation INSTALLER Pressure test the supply line for leaks. The appliance and its individual shut-off valve must be Window Flexible disconnected from the gas supply piping system during connector any pressure testing of that system at test pressures in supplied excess of 1/2 psig (3.5 kPa).
  • Page 41: Install Liners

    QUALIFIED Installation INSTALLER Install Liners Place the panel’s right section on the ledge above the ports of the rear of the fi rebox. The section sits The liners install in the manner outlined below with the on the ledge behind the tabs, with its plain edge on exception of the 1725RGL—Refl...
  • Page 42 QUALIFIED Installation INSTALLER 6. Place rear panel’s centre section on the ledge 10. Carefully lift, slide and position top panel on to left behind the tabs, slide it to the right so that its side and rear panel. stepped edge fi ts into the stepped edge of the rear panel’s right section.
  • Page 43: Install Long Beach Driftwood Kit

    QUALIFIED Installation INSTALLER Install Long Beach Driftwood Kit 3. Fill a small container with the equivalent of approximately 3 cups (750 ml) of vermiculite from Material required the bag supplied. • Middle platform brackets (supplied with appliance) • Vermiculite platform (supplied with appliance) •...
  • Page 44 QUALIFIED Installation INSTALLER Logs and rocks 4. Place the right rear log as indicated. Pivot tail end to Each log has pegs to help you locate them on the just cover small hole located in platform. platform. Install the logs as shown below. 1.
  • Page 45: Install Murano Glass Fire

    QUALIFIED Installation INSTALLER 6. Place centre cross log to rear log as indicated. Pivot 7. Some vermiculite may be added outside the burner tail end so tip is just inside fi replace window line. on the platform if desired. 8. Place the rocks on the platform as shown below. You can also place one or two rocks on the vermiculite as shown.
  • Page 46 QUALIFIED Installation INSTALLER 2. Install the sheet metal platform on top of the 4. Mix the black and blue fi re glass together. brackets as indicated. The edge of the burner 5. Fill a small container with approximately 3 cups protrudes above the platform.
  • Page 47: Refi T Window

    QUALIFIED Installation INSTALLER Refi t Window 1. To refi t the window, place it in its bottom railing and push its top against the fi rebox. Ensure there is no glass or vermiculite particles in the bottom Window frame railing. 2.
  • Page 48: Install Wall Switch Kit (Recommended)

    QUALIFIED Installation INSTALLER Install Wall Switch Kit (recommended) CAUTION DO NOT PUT BATTERIES IN THE REMOTE CONTROL RECEIVER OR THE BATTERY BOX until the wires are connected to the burner control unit as short-circuit could result in the Receiver Battery box in carrier destruction of the electrical components.
  • Page 49: Initialize Remote Control

    QUALIFIED Installation INSTALLER 8. Disconnect the battery box wire if already connected. 12. Slide the carrier towards the right hand side so 9. Remove the cover of the battery box (1 screw). that the battery box goes outside of the appliance case.
  • Page 50: Check Operation

    QUALIFIED Installation INSTALLER Check Operation adjustment should be determined only by operating the appliance with the fuel bed and window installed. Turn the fi replace fl ame up and down using the remote control to confi rm that the full range of inputs Increasing aeration will cause the fl...
  • Page 51: Install Remote Control Handset Wall Holder

    QUALIFIED Installation INSTALLER Install Remote Control Handset Wall Holder The remote control kit for this fi replace comes complete with a wall-mounted holder. This Packing Contents: Alternative 2 Alternative 3 holder is not required in all installations but 1 Wall Bracket A is provided as an optional feature for those 2 Screws B 1 Screw C...
  • Page 52: Wiring Diagram

    QUALIFIED Wiring Diagram INSTALLER Wall Switch Kit Connector Remote Battery Box 4 AA Batteries GV60 Wiring Diagram...
  • Page 53: Approved Venting Components

    QUALIFIED Approved Venting Components INSTALLER Approved Direct Vent Suppliers for Valor Models 1100, 1150, 1200 , 1500, 1600 and 1700 Venting Parts Code / availability by Manufacturer Venting Parts Description Standard Co-axial 46DVA-HC 4DT-HC TM-4HT — — 4DHC round 658DVK 940160 Deluxe Co-axial —...
  • Page 54 fi nishes: a) aluminium; b) black powder coated; c) solid copper. 5. Miles Industries Valor Co-linear adapter 1156CLA cannot be used with models 1200 and 1600. Use only with models 1100, 1150, 1500 and 1700. 6. Only Miles Industries Valor Co-linear adapter 1156CLA can be used with models 1700.
  • Page 55: Warranty

    1. Extended Warranty Coverage For a period of up to ten (10) years, Miles Industries Ltd., (the “Company”) or its appointed distributor will at its option pay the initial purchaser for the repair of, or will exchange the following parts or components which are found to be defective in material or...
  • Page 56: Spare Parts

    OWNER’S Spare Parts INFORMATION Part Part Code Description Code Description Number Number Heat shield 4003049 Thermocouple interrupter 4001037 45 degrees fl anged elbow 0945M Pipe s/s fl ex 4000345 Elbow gasket 4002999 Handset wall holder 9000008 Top stand-offs (2) 4002985 Handset G6R H3T5-ZV (BJ) 4001910 Restrictor plate...
  • Page 57 OWNER’S Spare Parts INFORMATION Part Code Description Number LH front log 4002967 Center cross log 4003721 RH rear log 4003928 RH Cross log 4003929 Brown beach pebble 4003082 Grey beach pebble (2) 4003083 Small grey beach pebble 4003086 White beach pebble (2) 4003084 Black beach pebble (2) 4003085...
  • Page 58 OWNER’S Spare Parts INFORMATION 15a, 15b 25-26 20-24 28a, 28b 37a, 37b...
  • Page 59 Serial Number: Date Purchase (yyyy-mm-dd): Dealer: Customer Information First Name: Last Name: Contact Information Email: Mailing Address Address: City: Province/State: Postal/Zip Code: Country: Cut out page, fi ll information, and mail to Miles Industries Ltd. Online Warranty registration at www.valorfi replaces.com...
  • Page 60 Tape Shut Fold here Postage needed Miles Industries Ltd. 190 - 2255 Dollarton Highway North Vancouver, BC V7H 3B1 Canada Online Warranty registration at www.valorfi replaces.com Thank you for choosing a Valor Product...

Table of Contents