LD2
ADDITIONAL PROTECTION
for new or materially altered dwellings or existing dwellings
with poor structural fire precautions
Additional Protection LD2: As LD3, but in addition
Smoke or Heat Alarms in all rooms or areas that
present a high fire risk to occupants.
Smoke Alarms located:
on each storey
every 7.5 m of hallways and escape routes
within 3m of all bedroom doors
(apart from toilets & bathrooms
Heat Alarms located in:
each Kitchen
(Heat Alarms must be within 5.3m of potential fire
sources)
Smoke or Heat Alarms located in:
each Living room (i.e. most frequently used
daytime room)
Bedroom
Bedroom
Living
Room
Bedroom
Bedroom

Single Storey Dwelling LD2

Ionisation or Optical
Smoke Alarm
Heat Alarm
Shower
Bathroom
Kitchen

Multi Storey Dwelling LD2

Bathroom
Bedroom
6
)
Garage
Kitchen / Dining Room
Living Room
Optical Smoke Alarm
do not fit alarm