Rear Panel - Panasonic AJ-RC10G Operation Manual

Remote control unit to ag-hpx500p/e
Hide thumbs Also See for AJ-RC10G:
Table of Contents

Advertisement

Available languages

Available languages

Parts and functions

Rear panel

!2" !1"
!6"
VIDEO OUT
!3"
!1" Camera connection connector
To connect the 10-pin camera control cable.
Pin No.
1
8
2
7
9 10
3
6
4 5
!2" VIDEO OUT connector
An NTSC or PAL monitor is connected for
operating the menu on the main unit of the
camera recorder.
!3" Cable length selector switch
This switch is on for a 50 m cable.
!4" Frequency characteristics
adjustment volume
This adjusts the frequency characteristics of
the VIDEO signals.
!5" Level adjustment volume
This adjusts the level of the VIDEO signals.
E-13
(Continued)
CAM RCU
CABLE
FREQUENCY
LEVEL
50m
10m
!5"
!4"
Signal
1
CAM DATA (H)
2
CAM DATA (C)
3
CAM CONT (H)
4
CAM CONT (L)
5
ECU_ON
6
Video input
7
GND (Video)
8
Standby
9
+12 V (IN)
10
GND
!6" Covering screw
The unit can be used when the four screws
are removed. However, do not leave the unit
without these screws for long periods of
time. When the screws are not in use, they
must be stored safely.