Parts and their functions

Rear panel

 POWER switch [POWER]
When the POWER switch is set to the ON position, the POWER
indicator (1) lights, and the unit can be operated.
 TO PAN/TILT HEAD 1 to 5 connectors
[TO PAN/TILT HEAD 1 to 5] (RJ-45)
Connect remote cameras that support a serial connection to these
connectors with LAN cables.
Connect them with straight cables (category 5 or above).
 LAN connector [LAN] (RJ-45)
(10BASE-T/100BASE-TX)
Connect a remote camera, switcher or computer that supports an IP
connection to this connector with a LAN cable.
When directly connecting a device to the unit, use a crossover cable
(category 5 or above).
When connecting via a hub (switching hub) or other device, use a
straight cable (category 5 or above).
 TALLY/GPI connector [TALLY/GPI]
JST: JBY-25S-1A3F(LF)(SN)
Connect an external device to this connector to receive tally
information or send the camera selection status.
 REMOTE connector [REMOTE]
JST: JEY-9S-1A3F(LF)(SN)
Connect an external device to this connector when you want to
control remote cameras from an external device.
 LCD CONTRAST control [LCD CONTRAST]
Use this to adjust the contrast of the LCD panel (3).
18
(continued)
 DC IN socket [12V
IN] (DC 12 V)
Hirose Electric: HA16RA-4P(77)
Connect an external DC power supply to this connector.
Pin number
Function
1
GND
2
NC
3
NC
4
+12 V
About the external DC power supply
z Make sure that the output voltage meets the voltage rating of the
z
unit before you connect the external DC power supply.
z Choose an external DC power supply with an output current
z
rating that is the same as or higher than the input current rating
of the unit.
z Inrush current occurs when the power of the unit is turned on.
z
Insufficient power supply capacity at power on may cause a
failure. We recommend using an external DC power supply that
provides at least twice the power consumed by the unit.
z Check the pin assignment of the DC output terminal
z
(DC plug) of the external DC power supply and the pin
assignment of the DC IN terminal on the unit, and connect
the terminals with the correct polarity.
z Incorrect connection of the +12 V power supply to the
z
GND terminal may cause a fire or failure.
 Grounding terminal [SIGNAL GND]
Connect this to the system ground.
 Wire fastening hole
A commercially available anti-theft wire can be fastened to this hole
to prevent theft.