Tea- Steamboiler at initialisation of the machine:
A timeout of 240 seconds occurred during initialisation of the tea
or steam boiler.
Check that the water supply is on. If it is, there is possibly a leak
or a pipe is blocked, e.g. due to scale...
The brewing unit motor did not start up within 0.5 seconds of the
command inputted (no increase in current). The motor is possibly
not connected or is defective.
The brewing unit motor was switched on for >30 seconds while
being moved down, or alternatively is at the lower end-point. The
current measurement is possibly defective.
The brewing unit motor was switched on >30 seconds while
moving up, or alternatively is at the upper end-point. The current
measurement is possibly defective.
The brewing unit motor was switched on for too long during
brewing, rinsing or cleaning. The current measurement is possibly
defective.
The brewing unit motor reached an end-point during calibration.
An increase in current was measured for >0.3 seconds by AD630.
It is possible that the position switch is not connected or is
defective.
An error occurred while reading the header info. Either the
chipcard or the reader contacts are dirty, or the card is
Delete the chip card (except the Install card)
Invalid manufacturer code. (The RID is invalid). The card cannot
be used on Evolution.
Invalid manufacturer code. (The PIX is invalid). The card cannot
be used on Evolution.
This type of card is not supported by Evolution.
An error occurred while reading the data block.
Either the chipcard or the reader contacts are dirty, or the card is
defective. Delete the chip card (except the Install card)
The installation number is incorrect. It is meant for a different
device.
The card is no longer useable, because no more error-counter
bits are available (max. 8) (There were repeated attempts made
to write an incorrect PSC to the card.)
A card with an incorrect write-protect code is in the reader.
Caution! The card will become unreadable after eight failed
readings, even on a device with the correct code. ð Error 57
A timeout occurred while writing to the card.
Either the chipcard or the reader contacts are dirty, or the card is
defective. Delete the chip card (except the Install card)
A verification error occurred while writing to the card.
chipcard or the reader contacts are dirty, or the card is defective.
Delete the chip card (except the Install card).
defective.
Either the
page 29 / 33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents