not full
3. Refrigeration quantity of compressor
is reduced.
Evaporator
frosts too
rapid, frost
1. Food put into freezer contains water.
layer too thick
2. Too much food has been stored.
or frozen to
ice
Electricity
1. Freezer body has not been connected
leakage
of
to the ground.
freezer body,
2. The compressor terminal contacts body
you will feel
shell and causes short circuit.
tingle
when
3. When the components of electrical
touching
by
system get wet, insulation ability is
hand
dropped, electricity leaks.
1. Environment temperature too high or
Electricity
insulation ability of insulator is dropped.
leakage
of
2. There is short circuit between fan coils
fan
or the fan coil is burned.
1. The blade of fan is blocked or fan
Fan too noisy
supporter is loose.
2. The clearance of fan axle is too big.
The
fan
1. Check if any connection has come off.
doesn't run
2. Check is the fan is burned.
Electricity
1. The service time is too long.
leakage
of
temperature
2. The environment is too dirty.
controller
3. Humidity is too high.
1. There is leakage of temperature
Temperature
sensing medium.
controller out
2. Damage of cam of contacting point
of order
spring, etc.
The probe of
temperature
sensing tube
It has not been mounted to position or
doesn't
changed during transportation.
contact
evaporator
well
2Clean the capillary and filter.
3.Change compressor.
1. Please let or make food dry
after cleaning, then store it.
2. Store only corrects quantity of
food.
1. Make the ground connection
as stipulated.
2. Change compressor.
3. Check carefully step by step, if
insulation is seriously damaged,
please change; remove wet parts
and put them into drying box to
make them dry.
1. Change fan.
2.Change fan.
1. Clear obstacles around the
fan or tighten the supporter.
2. Change the fan.
1. Change the fan.
2. Change the fan.
1. Change
controller.
2. Use brush to remove dust.
3. Make the temperature dry
and control the environment
humidity.
Change temperature controller.
Mount it again.
temperature