Haier BD-103GC Service Manual page 21

Chest freezer
Hide thumbs Also See for BD-103GC:
Table of Contents

Advertisement

runs
without
been set to "over cooling" position.
stop,
2.The contacting point of temperature
temperature
controller is adhered.
in freezer is
3.The temperature sensing probe of
too low
controller is not placed well, and causes
maladjustment
4.Compressor efficiency reduced.
Compressor
buzzes and
1. Voltage is too low.
cannot be
started,
2. Starting relay out of order.
thermal
3. The starting coil of starting motor is
protection
broken.
unit jump
4. Compressor does not run.
repeatedly.
1. The voltage is too high.
2. Over load protection unit is not good, it
After short
jumps earlier.
time of
3. Starter contacting point is adhered.
operation,
4. There is short circuit in compressor.
over load
5. There is mechanical problem in the
protection
compressor.
unit cuts off
6. Temperature around compressor is too
high.
1. The floor is loose.
2. The freezer body is not stable and in
level.
3. When
between tubes and freezer body causes
Too
much
resonance.
noise
when
4. Compressor fixing screw is loose.
compressor
5. The vibration absorption cushion for
runs
compressor fixing is too tight, or too
loose or ageing.
6. Compressor inside noise is too big or
vibration absorption suspending spring
is broken.
1. There is serious leakage of
There is no
refrigerant.
frost at
2. There is dirt blocked the capillary or
evaporator
system.
Frost
at
1. There is some leakage of refrigerant.
evaporator is
2. There is dirt block, but not serious.
compressor
runs,
moderate.
2. Repair or change.
3. Adjust to suitable position,
normally contact tightly with
evaporator cover.
4.Change compressor.
1. Supplement
adjust to rated value.
2. Change starting relay.
3. Change compressor.
4.The shaft and piston in the
compressor is blocked, please
change.
1. Supplement a stabilizer and
adjust its value to rated.
2. Change over load protection
unit.
3. Change starting relay.
4. Change compressor.
5. Change compressor.
6.Increase heat radiation space.
1. Reinforce the floor.
2. Make the freezer body stable.
friction
3. Move the tube a little away to
avoid friction.
4. Make the screw tight.
5. Adjust the degree of tight or
loose of vibration absorption
cushion, or change cushion.
6. Change compressor.
1. Check
welding
refrigerant again.
2. Clean the capillary or change
filter.
1. Check leakage, make welding
repair, and fill refrigerant again.
a
stabilizer,
leakage,
make
repair,
and
fill