Canon PIXMA MX310 Service Manual page 7

Hide thumbs Also See for PIXMA MX310:
Table of Contents

Advertisement

##220
TX / RX
##224
TX / RX
##226
TX / RX
##229
RX
##232
TX
##237
RX
##238
RX
##261
TX / RX
##280
TX
##281
TX
##282
TX
##283
TX
##284
TX
##285
TX
##286
TX
##287
TX
##288
TX
##289
TX
##290
TX
##670
TX
##671
RX
##672
TX
##673
RX
##674
TX
##675
RX
System error (main program hang-up)
An error has occurred in the procedure signal in G3 transmission.
The stack pointer has shifted from the RAM area.
The recording area has been locked for 1 minute.
The encoder control unit has malfunctioned.
The decoder control unit has malfunctioned.
The print control unit has malfunctioned.
A system error has occurred between the modem and the system
control board.
Re-transmission of the procedure signal has been attempted the
specified number of times, but failed.
Re-transmission of the procedure signal has been attempted the
specified number of times, but failed.
Re-transmission of the procedure signal has been attempted the
specified number of times, but failed.
Re-transmission of the procedure signal has been attempted the
specified number of times, but failed.
After TCF transmission, DCN has been received.
After EOP transmission, DCN has been received.
After EOM transmission, DCN has been received.
After MPS transmission, DCN has been received.
After EOP transmission, a signal other than PIN, PIP, MCF, RTP,
RTN has been received.
After EOM transmission, a signal other than PIN, PIP, MCF, RTP,
RTN has been received.
After MPS transmission, a signal other than PIN, PIP, MCF, RTP,
RTN has been received.
In V.8 late start, the DIS V.8 ability from the receiving machine was
detected, and CI was sent in response; however, the procedure
failed, causing T1 time-over.
In V.8 call reception, the procedure fails to proceed to phase 2 after
CM detection, causing T1 time-over.
In V.34 transmission, the procedure fails to proceed from phase 2 to
phase 3 or later, causing T1 time-over
In V.34 reception, the procedure fails to proceed from phase 2 to
phase 3 or later, causing T1 time-over
In V.34 transmission, the procedure fails to proceed from phase 3 or
4 to the control channel or later, causing T1 time-over
In V.34 reception, the procedure fails to proceed from phase 3 or 4 to
(7/32)