INSTALLATION

Baseboard Distribution

Figure 1
24 V Transformer
Line 1
Line 2
Return to outdoor furnace
From outdoor furnace
Outdoor furnace
circulating pump

Common Header Set Up

Pump can be wired through an in-line thermostat. Each zone can be manually adjusted with the ball
valves on the supply header. Adjust mixing valve to run entering water temperature between 110˚F - 120˚F
(43˚C - 49˚C) in concrete floor installations.
16
Baseboard unit
Thermostat
3 way
zone valve
Pool & Spa Hookup
Figure 2
To Cozeburn
furnace
POOL
HEATER
Bypass
From Cozeburn
COZEBURN INSTALLATION AND OPERATION MANUAL
Immersion
control
To pool
or spa
Black
wire
110
black
24 V
110
lines
white
24 V
Transformer
From pool
or spa