Pro-Fab Industries Empyre Elite XT Installation And Operation Manual

Pro-Fab Industries Empyre Elite XT Installation And Operation Manual

Hot water heater
Table of Contents

Advertisement

Quick Links

Empyre Elite XT
Model 100 and 200
Installation and
Operation Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Empyre Elite XT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pro-Fab Industries Empyre Elite XT

  • Page 1 Empyre Elite XT Model 100 and 200 Installation and Operation Instructions...
  • Page 3: Table Of Contents

    Table of ConTenTs Introduction ............................... 3–4 The Empyre Elite XT Hot Water Furnace ....................... 3 How The Empyre Elite XT Works ........................3 Serial Number Information ..........................4 safety ................................. 5–7 Safety Precautions ............................5 Safety Alert Symbol ............................6 Signal Words ..............................
  • Page 4 Refractory Layout - Model 100 ........................26 Unit Dimensions - Model 200 ........................27 Brick Layout - Model 200 ..........................27 Refractory Layout - Model 200 ........................27 troubleshooting ..............................28 Warranty ............................... Back Cover EmpyrE ElItE Xt InstallatIOn and OpEratIOn manual...
  • Page 5: Introduction

    XT furnace, read the Installation and Operation Instruction Manual cover to cover and follow all instructions carefully. The Empyre Elite XT furnace has been designed for outdoor installation and has also been tested to meet UL Standard 391 - 2006/726-06 Standard C22.2 No.3 and CSA B366- 1-M91 for indoor central solid fuel fired furnaces, therefore it may be installed indoors.
  • Page 6: Serial Number Information

    Have this information available when contacting the dealer for service, warranty or other information. Model No. ______________________________ Serial No. ______________________________ 817978R00 EMPYRE ELITE XT HYDRONIC FURNACE EMPYRE ELITE XT - FOURNAISE HYDRONIQUE Á BRÛLAGE PROPRE □ □ Model No./Certifién de Modèle Serial No./ N° de Série ___________________________ Certified Heating Appliance CSA Standard B366.1-M91 UL Standard 391-2006/726-06 Standard C22.2 No.
  • Page 7: Safety

    • Read the manual carefully and read all decals on the In the event of loss of electrical power: Empyre Elite XT furnace. Should you have any questions 1. Open all flow-check and zone valves in the system. not answered in this manual, contact your dealer.
  • Page 8: Safety Alert Symbol

    Canadian Csa requirements DANGER Installation of the Empyre Elite XT as an add-on unit in the Canadian provinces and territories must comply danGEr: Indicates an imminently hazardous situation with requirements of CAN/CSA-B365, and changes...
  • Page 9 White neutral line 110 volts Black power line the heat being produced by the AC 60Hz furnace. EMPYRE ELITE XT - FOURNAISE HYDRONIQUE Á BRÛLAGE PROPRE Ground 3. When the power has returned, reset all check and zone valves and □ □...
  • Page 10: Features

    Identifying main Components - Front View 13-A 13-B 13-A 13-B note: Furnace shown is the Empyre Elite XT 200. Parts on the model 100 will have the same description but appearances may vary. description description Front Upper Cover 13-B Insulation Board Configuration...
  • Page 11: Indentifying Main Components - Rear View

    Identifying main Components - rear View note: Furnace shown is the Empyre Elite XT 200. Parts on the model 100 will have the same description but appearances may vary. description description Roof Right Side Panel Lifting Hook Supply Port 1” Elite XT 100, 1-1/4” Elite XT 200...
  • Page 12: Installation

    Floor* 0” (0 mm) *See Indoor Installation Requirements below. Outdoor Installation requirements 1. The Empyre Elite XT furnace must be installed on a level, noncombustible floor pad, such as concrete or patio blocks. 2. Install the furnace in a location that best suits wind direction for your home and building(s) and neighbouring residents.
  • Page 13: Foundation Dimensions

    Foundation dimensions 1. The water lines The specifications below provide a stable concrete pad must be properly for the Empyre Elite XT furnace. The open area indicated insulated to mini- by ‘E’ in the drawing provides a channel for plumbing mize heat loss. and electrical conduit.
  • Page 14: Outdoor Furnace Installation

    3.0 feet (0.9 m) above the highest point where it they are located. The Empyre Elite XT adds to that draw, exits the roof and be at least 2.0 feet (0.6 m) taller than making it important to ensure there is an adequate any point of the roof within 10.0 feet (3.04 m).
  • Page 15: Low Water Temperature Protection

    Important: Pump must always be in lowest part of prOVIdE lOW WatEr tEmpEraturE prOtECtIOn the water line system from the Empyre Elite XT to the In tHE dEsIGn OF tHE HEat dIstrIButIOn systEm building. Pump may be at the furnace or in the building.
  • Page 16 Empyre Elite XT Water Tank Pump Pump Closely Spaced Tees (See Note) Figure 3 Connect to Existing Boiler Pump Boiler Supply Pump Existing Boiler Empyre Elite XT Boiler Return Return from System Pump Plate Exchanger EmpyrE ElItE Xt InstallatIOn and OpEratIOn manual...
  • Page 17: Side Arm Installation

    Stainless Steel Water to Water Heat Exchanger, Figure 2, can be used in place To domestic of a side arm. heating system Hot water in from Pro Series furnace From bottom of hot water tank EmpyrE ElItE Xt InstallatIOn and OpEratIOn manual...
  • Page 18: First Fill

    Vent opening and water maintaining proper Water level level indicator When the water level is low, the Empyre Elite XT may be filled or topped up through the vent opening, Figure 1. starting the Fire in the Hot Water Furnace Once the Empyre Elite XT has been properly installed, all...
  • Page 19: Operation

    Empyre Elite XT 100 is 18” - 25” (45.7 cm - 63.5 cm) , the unburned wood which can cause logs to hang up. Elite XT 200 is 20” - 28” (50.8 cm - 71.2 cm).
  • Page 20: Daily Routine

    Fire Brick and Insulation 1. Do this when the fire has died down before reloading The secondary burn chamber of the Empyre Elite XT high furnace. Switch blower off. efficiency furnace is lined with high temperature insulation. 2. Open ash clean out door. It is designed to sustain high furnace temperatures and 3. Pull out ash tray.
  • Page 21: Blower Draft Setting

    To replace any of these components you off the furnace and then turn it back on. Wait at least 10 must contact your Empyre Elite XT dealer. minutes before turning it back on. This will avoid back pressure coughing through the chimney when the furnace nOtE: This is not a natural draft furnace.
  • Page 22: Maintenance

    See page 9. Tighten with a wrench. 9. All doors must be closed during operation. 10. Operate the backup heating system (gas, oil or electric) periodically to ensure that it will operate satisfactorily when needed. EmpyrE ElItE Xt InstallatIOn and OpEratIOn manual...
  • Page 23: End Of Heating Season

    It is the 7. Ensure the water reservoir is full during the non-heating responsibility of the owner to maintain yearly season to prevent corrosion inside the water jacket. water sample results on file. EmpyrE ElItE Xt InstallatIOn and OpEratIOn manual...
  • Page 24: Reference

    In normal operation, the probe temperature will be shown on the display. In case of an alarm or error, the following messages will be shown: Er = Memory error - - = Short-circuit probe error ∞ = Open probe error EmpyrE ElItE Xt InstallatIOn and OpEratIOn manual...
  • Page 25: Hot Water Wood Furnace Wiring Diagram

    DO NOT CONNECT THE ELECTRICAL COMPONENTS OF THIS UNIT TO ANY OTHER ELECTRICAL APPLIANCE. DO NOT MODIFY THE ELECTRICAL COMPONENTS OR ANY OTHER PART OF THIS FURNACE. MODIFICATION TO ANY PART OF THIS FURNACE WILL VOID THE WARRANTY. EmpyrE ElItE Xt InstallatIOn and OpEratIOn manual...
  • Page 26: How To Correct A Sticking Flapper

    Flap tab and notch Empyre Elite XT 100 - Gap to be - 3/8” (10 mm) Empyre Elite XT 200 - Gap to be - 3/4” (19 mm) EmpyrE ElItE Xt InstallatIOn and OpEratIOn manual...
  • Page 27: Furnace Specifications

    Contact your local dealer for more information on the options available for your furnace and to order furnace replacement parts. Identify parts by referring to components throughout this manual. Furnace replacement parts must be purchased through Pro-Fab Industries by your dealer in order to maintain the furnace warranty. EmpyrE ElItE Xt InstallatIOn and OpEratIOn manual...
  • Page 28: Unit Dimensions - Model 100

          Not shown Not shown             2535 Production Release DESCRIPTION     Not shown Revisions EmpyrE ElItE Xt InstallatIOn and OpEratIOn manual...
  • Page 29: Unit Dimensions - Model 200

    Insulation, Fibre Board, Front, Burn Chamber, Elite 200 Insulation, Fibre Board, Front, Burn Chamber, Elite 200 818532   Manifold, Precast, Brick, Elite 200     Revisions     EmpyrE ElItE Xt InstallatIOn and OpEratIOn manual...
  • Page 30: Troubleshooting

    EmpyrE ElItE Xt InstallatIOn and OpEratIOn manual...
  • Page 32 Empyre Elite XT Furnace except the warranty expressed the Empyre Elite XT line of furnaces or parts without thereby be- herein. ANY IMPLIED WARRANTIES, INCLUDING MERCHANT- coming liable to make similar changes in the furnaces or any of its ABILITY, OR FITNESS FOR A PARTICULAR PURPOSE, SHALL parts previously manufactured.

This manual is also suitable for:

Empyre elite xt 100Empyre elite xt 200

Table of Contents