Inputting scan settings manually

Settings for the final scan can be made in the index scan or prescan windows.
Input-resolution list box: values can be selected among the drop-down list or be
entered into the box directly. The input-resolution range is from 200 dpi to the
maximum resolution of 3200 dpi.
Output-resolution list box: values can be selected among the drop-down list or be
entered into the box directly. Output-resolution cannot be entered if pixel is selected in
the unit list box.
Input-size text box: input size is determined by either the cropping frame dimensions
or the values entered in the width and height boxes. The cropping frame will adjust to
any value entered. Input-size cannot be entered if pixel is selected in the unit list box.
Input-size lock button: to lock the input values. The cropping frame can be moved,
but not resized while this button is clicked. Clicking the button again releases the lock.
The input-size lock button cannot be used if pixel is selected in the unit list box.
Magnification text box: to set image magnification. This value is based on input and
output resolution, or output and input size. The magnification text box cannot be used
if pixel is selected in the unit list box.
54
A
DVANCED SCANNING
Job-name list box
Load Job button
Save Job button
Input-resolution list box
Output-resolution list box
Input-size text boxes
Input-size lock button
Magnification text box
Output-size text boxes
Output-size lock button
Unit list box
Reset button
Image-size display