Gree GWH09RB-K3DNA2C Service Manual page 66

Hide thumbs Also See for GWH09RB-K3DNA2C:
Table of Contents

Advertisement

Troubleshooting
(3) High temperature and overload protection diagnosis (AP1 here in after refers to the control board of the outdoor unit)
Mainly detect:
Is outdoor ambienttemperature in normal range?
After the outdoor and indoor fans operating normally?
Is the heat dissipation environment inside and outside the unit is good?
Is outdoor ambient temperature higher than 53?
Is heat dissipation of the indoor unit
Does the outdoor fan work normally?
Overheat and high
temperature protection
N
20 minutes after the complete
unit is powered off.
and outdoor unit abnormal?
N
Y
Replace the control panel
AP1
End
Normal protection, please operate it after the
Y
outdoor ambient temperature is normalized.
Improve the heat
Y
dissipation environment
of the unit
1. Check if the fan terminal OFAN
is connected correctly
2. Resistance between any two
N
terminals is measure by an ohm
gauge and should be less than 1K
Ohm.
Replace the fan
capacitor C1
Replace the
outdoor fan
63