10-12
Error messages
Error messages are shown on the display
(panel in idle state).
Battery low:
if voltage sinks to under 10.5V,
the heating system will switch
off. Automatic reset to above
11V.
Fan failure:
incorrect fan speed. Automatic
reset after 5 minutes.
Gas failure:
gas bottle is empty. Reset by
switching off or restart.
Overheating is red: to reset, interrupt the 12V
electric power supply and
connect it again.
Overheating is blue: to reset, interrupt the 12V
electric power supply and
connect it again.
Window is open:
the heating system interrupts
the gas supply when the
window is open. Shut the
window.
Connection failure: connection error between the
heating system and the panel.
Switch the main voltage off
and then on again.
Panel failure 1:
panel error
Panel failure 2:
panel error