MAINTENANCE
1)
Use only approved chemicals at the recommended mix ratios. All chemicals should be added through the feed system and NOT added
directly to the water in the solution tank to prevent possible damage to the pump, seals, or other components.
2)
For optimum performance, fl ush the Chemical Feed lines after every job by replacing the chemical containers with containers of clear water
and spraying through the gun until the fl uid stream is clear. See the Maintenance Schedule, below.
3)
The pump seals and/or valves in the high pressure pumps may need to be replaced after about 1000 hours of use, if the pump begins to lose
performance or to leak. The pressure regulator valve may need to be when a drop in the spraying pressure at the tool is apparent.

MAINTENANCE SCHEDULE

ITEM
Flush chemical lines
Check/clean vac inlet fi lter
Clean solution fi lter
Check vacuum motor airways
Check pump for leaks
Check vacuum motor brushes *
* Have your distributor check the carbon brushes once a year or after about 500 hours of operation.
TECHNICAL SPECIFICATIONS (as installed and tested on the unit)
MODELS
VACUUM MOTOR(s):
WATER LIFT:
AIR FLOW:
TANK CONSTRUCTION:
HEIGHT:
WEIGHT
DAILY
WEEKLY
X
X
X
X
X
600303281, 600303282
Two stage, 8 Amp
23 kpa
100 CFM
Rotationally molded polyethylene
98 cm X 59 X 86.5 cm
50 KG
YEARLY
X
FORM NO. 56041948 - APC 328 - 7