Changing the memory card

Never remove the card when the access lamp is red - the data or memory card
may permanently be damaged.
Windows 98 and 98 Second Edition
1. Turn off the camera.
2. Change the memory card.
3. Turn on the camera to remake the USB connection.
If Kodak EasyShare is installed, right click on the EasyShare icon on the task bar and quit the appli-
cation before disconnecting the camera.
Windows Me, 2000 Professional, and XP
1. Stop the USB connection using the unplug-or-eject-hardware routine (p. 108).
2. Turn off the camera.
3. Change the memory card.
4. Turn on the camera to remake the USB connection.
Macintosh
1. Stop the USB connection by dragging the drive icon into the trash (p. 109).
2. Turn off the camera.
3. Change the memory card.
4. Turn on the camera to remake the USB connection.

QuickTime system requirements

IBM PC / AT Compatible
Pentium processor-based PC
or compatible computer
Windows 98, Me, 2000, or XP.
128MB or more of RAM
110
Data-transfer mode
QuickTime is used for playing back movies. To
install QuickTime, follow the instructions in the
installer. QuickTime is not supplied with the camera
in all sales regions. Users can download the latest
version of QuickTime free of charge from the Apple
Computer web site at http://www.apple.com.

Uninstalling the driver software - Windows

1. Insert a memory card in the camera and connect it to the computer with the USB cable. Other
devices must not be connected to the computer during this procedure.
2. Right click on the My-computer icon. Select "properties" from the drop-down menu.
Windows XP: from the start menu go to the control panel. Click on the performance and mainte-
nance category. Click "System" to open the system properties window.
3. Windows 2000 and XP: select the hardware tab in the properties window and click the device-
manager button.
Windows 98 and Me: click the device-manager tab in the properties window.
4. The driver file will be located in the universal-serial-bus-controller or other-devices location of the
device manager. Click on the locations to display the files. The driver should be indicated with
Konica Minolta, the camera name, or "USB Mass Storage Device." Under certain conditions, the
driver name may be different. However, the driver will be indicated by either a question mark or
exclamation point.
5. Click on the driver to select it.
6. Windows 2000 and XP: click on the action button to display the drop-down menu. Select "unin-
stall." A confirmation screen will appear. Clicking "Yes" will remove the driver from the system.
Windows 98 and Me: click the remove button. A confirmation screen will appear. Clicking "Yes"
will remove the driver from the system.
7. Disconnect the USB cable and turn off the camera. Restart the computer.