Supply Gas Installation - Valor 700IN Owner's Manual

Table of Contents

Advertisement

The gas supply inlet connection is a 1/2" NPT female. A
gas shut-off valve is supplied on the end of a stainless
steel fl exible connector. The fl ex connector installs on
the left hand side of the appliance.
X
Use only new black iron or steel pipes or copper tubing
if acceptable—check local codes. Note that in USA,
copper tubing must be internally tinned for protection
against sulfur compounds.
The burner module and gas train on this appliance
may be removed as a unit for servicing. The fl ex pipe
supplied with the unit provides a union for removal of
the module.
Unions in gas lines should be of ground joint type.
The gas supply line must be sized and installed to
provide a supply of gas suffi cient to meet the maximum
demand of the appliance without undue loss of
pressure.
Sealant used must be resistant to the action of all
gas constituents including LP gas. Sealant should be
applied lightly to male threads to ensure excess sealant
does not enter gas lines.
Pressure test the supply line for leaks.
The appliance and its individual shut-off valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/2 psig (3.5 kPa).
1/2" NPT
Shut-off valve
female
(supplied with
appliance)
Valve Assembly

Supply Gas Installation

34" (864 mm)
Control
fl ex pipe
Valve
supplied with
appliance
Manifold
Pressure
Adjustment
behind
Plastic Cap
The appliance must be isolated from the gas supply
piping system by closing its equipment shut-off valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psi
(3.5 kPa).
Failure to either disconnect or isolate the appliance
during pressure testing may resulting regulator or valve
damages and void the warranty. Consult your dealer in
case of damages.
Pressure Test Points
The minimum supply pressure is given in the
section Specifi cations of this manual—page 17.
All piping and connections must be tested for
leaks after installation or servicing. All leaks
must be corrected immediately.
When testing for leaks:
• Make sure that the appliance is turned off.
• Open the manual shut-off valve.
• Test for leaks by applying a liquid detergent or
soap solution to all joints. Bubbles forming indicate
a gas leak.
Never use an open fl ame to check for leaks.
Correct any leak detected immediately.
The pressure test tapping locations is shown in the
fi gure below. An internal regulator within the valve
controls the burner manifold pressure.
The correct pressure range is shown in the table in
section Specifi cations of this manual on page 17. The
pressure check should be made with the burner alight
and at its highest setting. See Lighting Instructions
section for full operating details on page 16.
QUALIFIED
INSTALLER
Manifold Test
Pressure
Valve Inlet
Pressure
Pressure Testing
25