HEAVY FOG GLACIATOR
DISPLAY MESSAGES
The following list shows the messages possible, and the context under which
they are displayed. Only the messages available under normal operation are
shown. Messages shown when using the menus, are detailed in other
sections of this handbook.
Fog Display
Fog/oFF
Displayed when the Standby switch is set to OFF, indicating
that the machine can not be fired and the heaters are OFF.
Fog/Err
Shows that the Standby switch is ON but the heater is not
on. This is an error condition and should not normally occur.
Displayed when the heater is running but the machine is not
Fog/Ht
ready.
Fog/rdy
The machine is ready to fire using the Fog or Timer
switches.
Indicates that the fluid in the container is below the minimum
FLu/Lo
level to operate the machine. Only visible when the machine
has reached the ready state.
Fog/08
The FOG switch is being used to fire the machine. The
number displayed is the current Fog output level in the
range 0 to 20
Ice Display
dEn/oFF
Displayed when the Standby switch is set to OFF.
dEn/nor
Shows the current Density setting.
18
USER
GUIDE

SAFETY GUIDELINES

Always use JEM/Martin approved fluid in the container supplied with the
machine. Do not bypass the fluid sensor, this could cause damage to the
machine.
Check the voltage is correct for use with the machine, the voltage setting is
printed on the serial label.
The machine must be operated in a horizontal position and should not be
suspended overhead.
Observe the warnings displayed on the machine (yellow labels).
Do not remove the covers or attempt to repair a faulty machine, an autho-
rized JEM dealer should be contacted in the event of a faulty machine.
Always use smoke machines in well ventilated areas, over-use could affect
sufferers of asthma or other chest conditions.
Smoke machines can cause condensation to form. Floors and surfaces may
become slippery and should be checked regularly.
This machine is not waterproof, and should not be exposed to wet outdoor
conditions. Do not spill fluid over the machine. If fluid is spilt, clean with a
damp cloth and contact an approved JEM dealer for advice.
Refer servicing to qualified service personnel. Disconnect the machine from
the power supply before removing any covers.
Mains Cable Wiring Instructions
This equipment
must be earthed.
Brown = Live
Blue = Neutral
Green / Yellow = Earth
HEAVY FOG GLACIATOR
The Heavy Fog Glaciator is fitted with
an IEC 32A single phase connector. A
suitable 32A,230V supply must be
used.
On the 208V/60Hz version of the
machine, the IEC connector is
replaced by a fixed cable.
To connect to US 208V supplies, the
neutral conductor can be connected
to the second phase of the 120V
system, while phase 1 is connected to
the Live
conductor
.