Nikon One-Touch Zoom 90s One-Touch Zoom 90s AF Quartz Date Repair Manual page 56

Hide thumbs Also See for One-Touch Zoom 90s One-Touch Zoom 90s AF Quartz Date:
Table of Contents

Advertisement

Item
Electric
Zoom Zo
current
consumption
Zoom W
Zoom T
Zoom W
BC warning voltage
BC voltage
BC lock voltage
Battery life Film advance quantity
Standard of judgment
500mA or less/operating time: 1 second or less
W
Measure the electric current as pressing the
zoom button.
TYP of electric current consumption is approx.
300mA.
T
500mA or less/operating time: 3 seconds or less
W
500mA or less/operating time: 3 seconds or less
Zo
500mA or less/operating time: 1 second or less
·At 2.45 ~ 2.70V, the battery mark must
blink and release must be possible.
Other displayed items must be normal except the
battery mark.
·At 2.40±0.1V, the battery mark must
blink and release must be possible.
This voltage value is standard in a camera and
actual measurement is not possible.
After checking the battery mark on LCD, perform
release.
·At 2.25 ~ 2.50V, the battery mark must
blink and release must be impossible.
Others must be turned off except the battery
mark.
·At 2.20±0.1V, the battery mark must
blink and release must be impossible.
This voltage value is standard in a camera and
actual measurement is not possible.
·The BC warning voltage and BC lock voltge
must not be reversed in a same camera. (Elec-
tric potential difference: 0.1V or more)
·At 2.10±0.1V, LCD is turned off.
After checking the battery mark on LCD, perform
release.
·Normal temperature: When a film of 24
frames is used, you can take pictures of
15 films or more (on the condition that
speed light 50% is used).
·-5°C: When a film of 24 frames is used,
you can take pictures of 3 films or more
(on the condition that speed light 50% is
used).
Perform 13 shots of speed light flash at inter-
vals of 8 seconds and perform release con-
tinuously in the flash prohibition mode till
automatic return occurs.
Carry out zoom operation once every shot.
After rewinding is ended, load the next film car-
tridge at once.
- R6 • One Touch Zoom 90s AF -
FCA54001-R.3567.A
Method and tools
Ammeter/Power
supply (1)
Use the power
supply (2)
to measure the
operating time.
Power supply(3)
Visual check
Power supply(3)
Visual check
ISO100 24EX
Power supply(2)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents