Further Adjustments; Setting Delivery Times For Fuel Supply - Viessmann VITOLIGNO 300-P Operating Instructions Manual

Heating system with weather-compensated, digital boiler and heating circuit control unit vitotronic 300 type fw1
Table of Contents

Advertisement

Setting delivery times for fuel supply

The factory setting for the delivery time is "demand-dependent", meaning the supply
system is enabled automatically.
You can also set the delivery times individually, if required, so that filling the pellet
hopper is only allowed at certain times.
The delivery times should be selected in such a way that there is sufficient fuel should
the power fail temporarily.
Setting delivery times
Press the following keys:
1. "MENU".
2. |/~ for "Boiler".
3. d
to confirm.
4. |/~ for "Delivery times".
5. d
to confirm.
6. |/~ for "Individual".
Note
If you want to terminate the
settings for delivery times
prematurely, press
the standard display is
shown (see page 10).
7. d
to confirm.
Supply times
Monday – Sunday
Monday – Friday
Saturday – Sunday
8. |/~ until the required part of the
week or day appears.
9. d
10. |/~ for the selection of the time
11. d
12. |/~ for the starting point of the
g until
13. d
14. |/~ for the end point of the time
15. d

Further adjustments

to confirm.
Supply times
0
2
4
6
8
10
12 14 16 18 20 22 24
1
00:00 to 24:00 h
Select with
phase.
The respective time phase is
displayed by a number
(!, ?, § or $).
to confirm.
time phase.
to confirm.
phase.
to confirm.
Supply times
0
2
4
6
8
10
12 14 16 18 20 22 24
1
08:00 to 12:00 h
Accepted