10) Waveform / Vectorscope
Waveform enables users to check the luminance level. Vectorscope is for checking
chrominance values of the picture. The mode is switched in the order of :
Waveform, Waveform Parade, Vectorscope, Wide Waveform, Full-Screen
Waveform, Full-Screen Vectorscope.
* Some afterimage might be left on Waveform when the input picture
freezed long on interlace signal.
* On SDI 2K input with Psf scanning mode, displaying Circle or
Horizontal Line pattern might cause an afterimage effect. However, it
will be disappeared after the picture is changed.
11) False Color
Shows pictures in specific colors as its luminance level other than the original
colors. Much exposed area is filled with red while little exposed area is purple.
* 10-bit, 12-bit Dithered gradient pattern might not be displayed
clearly in this mode.
12) Power Button
Power turns off when pressed for one second.
13) Tally Lamp
Tally lamp displays Red, Green, Amber color tally.
14) Focus Assist
Displays focus area when pressed. The focus sensitivity is adjustable on the
display menu.
15) R/G/B/Gray Only
Displays Red, Green, Blue or Gray only as the button is pressed.
16) Audio Out
Stereo phone jack for audio output.
17) Menu Button
Menu and Exit button.
18) Knobs
Brightness, Contrast, Chroma, Volume adjustable knobs. The brightness knob is
also used as arrow knob to move up and down on the menu, User Zoom, etc.