Protective Dsp Settings - EM Acoustics EMS-122 User Manual

Fullrange passive loudspeakers
Table of Contents

Advertisement

Protective DSP Settings

The EMS-122 and EMS-122w require no DSP program to function correctly. However, excessive low frequency
information will cause the LF drive unit's excursion to increase, which can result in damage to your loudspeaker.
The higher you raise the high pass filter on an EMS-122, the more headroom and overall sound pressure level
output there is available. For most medium-to-high level applications, we would recommend a minimum of an
65Hz high pass filter with a 24dB/octave slope to sufficiently protect the loudspeaker. For higher SPL applications,
we would recommend raising this filter – we would stress that the higher the filter, the safer the loudspeaker will
be. If you are in any doubt over suitable settings for your EMS-122, please don't hesitate to contact EM Acoustics
or your local dealer for support and advice.
7
EMS-122/122w User Manual
www.emacoustics.co.uk

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ems-122w

Table of Contents