Page 3
Appendix B – Technical Drawings ......................28 Appendix C – Spare Parts List ........................33 Appendix D – Warranty Information ....................... 34 Limited Warranty ..........................34 Warranty Coverage ..........................34 Returning your EM Acoustics loudspeaker................. 34 EMS-129 User Manual v1 November 2019...
Page 4 of 34 DECLARATION OF CONFORMITY The products contained within this manual conform to the requirements of the EMC Directive 89/336/EEC, amended by 92/31/EEC and to the requirements of the Low Voltage Directive 73/23/EEC amended by 93/68/EEC. EMC Emission EN55103-1:1996 Immunity EN55103-2:1996...
LF drive unit and a 1.4” exit HF compression drive unit coupled to a rotatable constant coverage waveguide - 90° x 60° for the EMS-129, and 60° x 40° for the EMS-126. These two drive units are linked with an extremely comprehensive passive crossover network.
Page 7 of 34 FC-129h The FC-129h is a simple and effective means of mounting the EMS-129 in both Horizontal flying cradle temporary and permanent applications. It is secured to the cabinet by means of M10 socket head bolts into the top and bottom of the loudspeaker to mount it in a landscape format.
By default, the EMS-129 ships from the factory with the dispersion pattern 90° horizontal x 60° vertical when the loudspeaker is in a portrait format (60° horizontal x 40° vertical for the EMS-126). To rotate the waveguide: 1. Follow step 1 in the servicing chapter (Chapter 7) to remove the grille.
Windows (XP or Higher) only. It can also be downloaded directly from the EM Acoustics website with all the current product files embedded. Tutorials for Ease Focus 3 are available from with the application itself.
General Considerations in use Loudspeaker systems are potentially dangerous objects if used incorrectly. Please ensure that you read this section fully, and contact EM Acoustics or your local dealer should you be in any doubt over correct operation procedures. Personal Injury Never stand in the immediate vicinity of loudspeakers when in use at high level.
EM Acoustics loudspeaker product (unless where specifically stated) or any other loudspeaker system. The use of EM Acoustics accessories with other manufacturers’ systems may compromise the safety standards and EM Acoustics is in no way liable for any loss, damage or injury caused by such practice.
In most cases, annual independent tests & inspections carried out by a suitably approved and qualified inspector will be required. EM Acoustics recommends detailed logbooks be kept of all inspections and load tests to ensure an accurate record is kept of the testing for each EM Acoustics rigging accessory.
Page 14 of 34 5.2 – Using the FC-129v The FC-129v is intended to mount the EMS-129 vertically – either using a hook clamp or similar from above, or a pole mount adapter to mount on a stand yet allowing enclosure tilt.
Page 15 of 34 5.3 – Using the FC-129h The FC-129h is intended to mount the EMS-129 horizontally. To fit, lie the EMS-129 on its side and loosen the locking knobs so that the mounting plates can be rotated to allow access to the mounting bolt holes.
Page 16 of 34 5.4 – Using the DFB-129 To use the DFB-129 set, it is advised to position the two loudspeakers on the floor and secure the top plate as shown – ensuring that the flat and spring washers are both used on each bolt.
Page 17 of 34 5.5 – Using the VFA-129 The VFA-129 is designed to suspend the EMS-129 from a single point, using the centre of gravity of the loudspeaker to determine the up or down tilt angles. A moveable pickup point allows setting of the angle in 5-degree increments from +25°...
Page 18 of 34 5.7 – Using Powerdrive or Omnimount fittings EMS-129 loudspeakers are compatible with Powerdrive Series 100 or Omnimount Series 60 installation brackets. Using a 5mm Allen key, remove the four M8 countersunk socket head bolts on the rear of the EMS-129.
Page 19 of 34 6.0 – Powering the System The EMS-129 can be powered from any amplifier & DSP combinations with the relevant high & low pass filter, and limiter settings. However, due to the self-contained nature of the package, the use of DQ Series advanced system amplifiers is highly recommended. The use of DQ Series amplifiers provides a neat and flexible system that will encompass all requirements for the system to function correctly, as well as providing user control for room EQ and system alignment.
If not using DQ Series amplifiers, or the DSC48 Digital System Controller, then a suitable DSP system must be used in conjunction with your EMS-129 to prevent damage to the loudspeaker. Check the EM Acoustics website for the most up-to-date DSP settings for the EMS-129.
Page 21 of 34 6.2 - Presets and Settings 6.2.1 – Standard EMS-129 Preset When used with a DQ Series amplifier EMS-129 loudspeakers require only a single amplifier channel, and as such the preset recalled will only require one output from your DQ Series amplifier.
EMS-129 loudspeakers require one amplifier channel. 6.3.2 - Preset Recall The EMS-129 and EMS-126 presets are pre-installed on DQ amplifiers, and as such can be used following the normal preset recall procedure. The presets available are: EMS-129.full Standard EMS-129 preset EMS-126.full...
Because pins 2+/2- are linked through inside all EM Acoustics loudspeakers, using a 4-core cable to one loudspeaker (carrying two different signals) allows a crossover cable to be used to link out of the first loudspeaker into another, thereby feeding it from a separate signal.
Page 24 of 34 7.0 – Servicing Information All EMS-129 components can be removed for service purposes if required, using the minimum of tools. 7.1 – EMS-129: Removing the grille TOOLS REQUIRED: 4mm Allen key Lie the enclosure on its’ back and remove the two M6x30 countersunk socket screws from each end using a 4mm Allen key, and then lift the grille clear of the cabinet.
Page 25 of 34 7.2 – EMS-129: Removing the LF drive unit TOOLS REQUIRED: 5mm Allen key Complete step 7.1 above to remove the grille. Using a 5mm Allen key, remove the eight M6x30 socket cap screws that secure the drive unit. Ensure that you collect the spring washers as well as the machine screws.
Page 26 of 34 7.3 – EMS-129: Removing the HF drive unit TOOLS REQUIRED: 4mm Allen key Complete step 7.1 above to remove the grille. Using a 4mm Allen key, remove the eight M6x40 countersunk socket screws that secure the waveguide.
Serial numbers must be quoted in all correspondence relating to the claim. EM Acoustics or its representatives are in no way liable for any loss or damage in transit, and hence it is recommended that the sender insure the shipment. EM Acoustics will pay for return freight should the repair be covered under warranty.