Protective mechanisms and self-
regulation
When a deviation from normal operation takes place the LED
will start blinking very frequently to attract the operator's
attention. This can occur e.g. if the motor temperature is too
high, if overload occurs or when the drill motor has gone
through the work piece and the unit stops feeding.
When the LED flashes at a high rate the drill motor cannot be
used. The feed capability can be activated by turning the
potentiometer to its zero position. The LED then flashes at a
lower rate. Press the power switch button once again to stop
the feed unit. The unit must be shut down entirely to return to
the normal mode.
When the drill has gone through the concrete, the power
goes down. When the power has been below a certain
value for a certain time period, the unit will automatically
stop feeding down and switch the drill motor off.
If the power to the unit's feed motor is too high and is about
to become overloaded, the feed unit will shut down. This
can occur when drilling using drill bits with a diameter less
than 100 mm, when drilling in very soft concrete, in the
case of incorrect assembly or if the feeder housing is too
rough on the column. Modify the feeding speed and do not
put excess load on the drill motor!

Starting and stopping

Before starting
Check that the machine is assembled correctly and do not
show any signs of damage. See instructions in the section
"Assembling and adjustments".
Check that the emergency stop button is not pressed by
turning it clockwise.
Check that the potentiometer is in the zero position.
Starting
Push the power button. The LED is continually lit and
indicates that there is voltage to the outlet on the unit.
Note! This applies to drilling machines fitted with a
ground fault circuit interrupter. If the ground fault circuit
interrupter on the machine is triggered, it is at this point that
the ground fault circuit interrupter can be reset.
Start the drill motor. See instructions in the operator' s
manual for the drill motor used.
OPERATING
Turn the potentiometer to the desired position to start the
feeding.
If the drill motor is equipped with an overload indicator,
this can be used as a visual aid to set the right feeding
speed.
To optimize use, you should let the machine work on its
own once the right feeding speed is obtained.
Stopping
Press the power switch button to stop the feed unit.

Transport and storage

Always switch of the feed unit and pull out the electric
cable before moving the equipment.
Use the cases provided to store the equipment.
Secure the equipment during transportation in order to
avoid transport damage and accidents.
Store the equipment in a lockable area so that it is out of
reach of children and unauthorized persons.
Store the machine and its equipment in a dry and frost
proof place.
Do not expose the machine to temperatures exceeding
45°C or to direct sunlight.