4. PRECAUTIONS

1. Installation

1
The e-STUDIO160/200/250 should be installed by an authorized TOSHIBA service
1
technician.
Note
The packing material should be disposed of properly.
2
2
To obtain the best possible results, this machine should be used in conjunction with
a dedicated AC power line at the following ratings:
110-127 VAC, 50/60 Hz, 1.4 kW or less
3
Note
1. The use of other appliances or other equipment on the same line as this machine may adversely
4
affect performance and copy quality.
2. Be sure to use a 3-conductor, grounded wall outlet.
3. In areas where a 2-pin plug is used, the digital multi function system must be grounded for safety.
Never ground it to a gas pipe, a water pipe, or any other object not suitable for grounding.
5
3
After a suitable place has been selected for installation of the e-STUDIO160/200/250,
please avoid frequent movement. Avoid excessive heat, dust, vibration and direct
sunlight. Also, provide proper ventilation as the digital multi function system emits a
6
small amount of ozone.
Note
1. The recommended environmental range for use is as follows:
7
• Temperature:
• Humidity:
2. To ensure optimal operation, allow clearances of at least 32" on the left, 32" on the right and 4" in
the rear (refer to the illustration below).
8
9
10
11
12
The e-STUDIO should be placed near an outlet that is easily accessible.
8
PRECAUTIONS
10~30°C/50~86°F
20~85% RH
4 inches
32 inches
32 inches