Specifications
Environmental specifications
Specification
Temperature range*
Operating
Nonoperating
Relative humidity
(noncondensing)
Operating, maximum wet bulb
temperature of 28°C (82.4°F)
Nonoperating, maximum wet
bulb temperature of 38.7°C
(101.7°F)
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
Server specifications
Specification
Dimensions (with feet/bezel)
Height
Depth
Width
Weight (approximate)
Maximum (all hard drives, power
supplies, and processors installed)
Minimum (one hard drive, power
supply, and processor installed)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
•
HP ProLiant 460 W non-hot-plug power supply
Specification
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Value
10°C to 35°C (50°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
10% to 90%
5% to 95%
Value
—
43 cm (16.93 in)
63 cm (24.80 in)
20 cm (7.87 in)
—
27 kg (59.53 lbs)
20 kg (44.09 lbs)
Value
100 to 240 V AC
50 Hz to 60 Hz
6 A to 3 A
Specifications 110