3-3 Specifications

Dryer unit
Power requirements
Power consumption
Weight
Environment
Included items
*1
Warm-up is required after powerup. This may require 5 to 20 minutes, depending on the operating environment.
Depending on the ambient temperature and media width, the preset temperature may fail to be reached.
*2
Be sure to connect the machine to an unshared electrical circuit.
Be sure to verify the amperage of the circuit breaker or fuse used.
*3
Operating environment
*4
When this unit is used with a printer equipped with a cutting feature, no assurance is made with respect to the following points. Refer also to the
user's manual included with the printer.
Distance accuracy (when cutting)
Repetition accuracy (when cutting)
Repetition between printing and cutting
Alignment accuracy for printing and cutting when reloading media
32
Chapter 3 Appendix
Heating type (with blower fan), setting range for the preset temperature: 30 to
55°C (86 to 130°F)
AC 100 to 120V ±10%, 5.5 A, 50/60 Hz or AC 220 to 240 V ±10%, 3 A, 50/60 Hz
(*2)
Approx. 750 W
26 kg (57 lb.)
Power on
Temperature: 15 to 32˚C (59 to 90˚F)––(20˚C (68˚F) or more recommended), humid-
(*3)
ity: 35 to 80% (no condensation)
Power off
Temperature: 5 to 40˚C (41 to 104˚F), humidity: 20 to 80% (no condensation)
Power cord, arms, bushing, cable clamps, stays, hexagonal wrench, bolts, washers,
User's Manual
Use in an operating environ-
ment within this range.
DU2-64
(*1)