Cleveland KEP Repair Manual

Pedestal electric self-contained kettle

Advertisement

Quick Links

Repair Manual
Pedestal Electric
Self-Contained Kettle
Model KEP
UNITED STATES
1333 East 179th St., Cleveland, Ohio 44110
Phone: (216)481-4900 • Telex: 98-0546 • FAX: (216) 481-3782
Cleveland Range, Inc.
CANADA
Garland Commercial Ranges
1177 Kamato Road
Mississaugha. Ontario. Canada L4W7X4
Phone: (416) 624-0260 • FAX: (416) 624-0623
KET-13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KEP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cleveland KEP

  • Page 1 Self-Contained Kettle Model KEP Cleveland Range, Inc. UNITED STATES CANADA 1333 East 179th St., Cleveland, Ohio 44110 Garland Commercial Ranges Phone: (216)481-4900 • Telex: 98-0546 • FAX: (216) 481-3782 1177 Kamato Road Mississaugha. Ontario. Canada L4W7X4 Phone: (416) 624-0260 • FAX: (416) 624-0623...
  • Page 2: Limited Warranty

    Cleveland Range agrees to repair or replace, at its option, f.o.b. factory, any pan which proves to be defective due to defects in material or workmanship during the warranty period, providing the equipment has been unaltered.
  • Page 3 MODEL KEP OPERATING CONTROLS AND INDICATORS For your better understanding and confidence, the following explanation of the control system used on this kettle is offered. Item No. Description Function On-Off Toggle Switch (Kettle Controls electrical power to the kettle. Bottom Dwg.)
  • Page 4 MODEL KEP KETTLE BOTTOM Item No. Part No. Description Qty. FI05025 Bleed Vent Elbow KE50570 Bleed Vent Nut FI05022 Connector KE50556 Probe - Low Water KE50998 Safety Valve 55 PSI. KE50997 Blow Down Tube KE50504 Toggle Switch KE50568 L.E.D. Green...
  • Page 5 MODEL KEP CONTROL SYSTEM Item No. Part No. Description Qty. KE51322 Contactor (Furnas) KE00458 Kettle Control Box KE50752 Transformer KE50753 Relay KE51225 Edge Connector KE51226 Connector Pin KE50376 Terminal Block - End Section KE50377 Terminal Block Section Use only replacement parts which are factory supplied as to preserve the certification of Underwriters Laboratories, American Gas Association.
  • Page 6 HINGE ASSEMBLY FOR ALL KETTLES WITH HINGED LIDS Item No. Part No. Description Qty. KE00598 Hinge Assembly KE50822 Body Spring Assist Hinge KE50824 Hinge Bearing KE50823 Pin(Hinge) KE50820 Insert Brass Adjust KE50819 End Piece FA11507 Screws Adjust FA11284 Bolts End Block KE50122 Spring (40 gal.
  • Page 7 ALL KETTLES PARTS LIST - DRAW-OFF VALVE Item No. Part No. Description Qty. KE50219 1 1/2" Draw-off Valve Assy. KE50972 2" Draw-off Valve Assy. KE50973 3" Draw-off Valve Assy. Body (1 1/2') (N/A, Please order Hem no. 1-7, Pan no. KE50219) Body (2") (N/A, Please order Item no.
  • Page 8 KETTLE AND SKILLET FAUCET Item No. Part No. Description Qty. SE50020 Hot Water Stem Assy. SE50021 Cold Water Stem Assy. SE50022 Yoke Connection Kit FA00016 "0" Ring FA95022 Retaining Ring KE51404 Spout Nut see chart 3/4" spout (please see 3/4" spout chart below) 3/4"...
  • Page 9 KETTLE AND SKILLET FAUCET...
  • Page 10 ALL ELECTRIC KETTLES SERVICING GUIDE This section contains servicing information intended for use by Authorized Service Personnel. Note 1: If Fault Isolation Procedure is required, be sure to start at step #1, Note 2: On table top kettles the entire control mounting panel may be removed from kettle control housing for easier troubleshooting and parts replacement.
  • Page 11 Remove wire from low water level probe and Clean or replace defective low water level ground it to the body of the kettle. Do the probe. Replace detective red LED. contactors now energize? Go to step #8. Is there 16 VAC present at output of 16 VAC Go to step #9.
  • Page 12 Unplug control box and measure the Go to step #5. resistance across potentiometer. Is it approx. Replace defective potentiometer. 0 ohms at max. and 50.000 ohms at min. settings? Remove kettle thermistor and allow to cool. Go to step #6. Remove edge connector from control box.
  • Page 13: Hinge Adjustment Instructions

    HINGE ADJUSTMENT INSTRUCTIONS Insert 3/8" Allen wrench. Turn clockwise to relieve tension on spring. While tension is released remove one of the two slotted screws. To prevent Allen wrench from springing back abruptly while the second slotted screw is removed, insert a pin (approximately 1/8") in the hole where the first slotted screw was removed from.
  • Page 14 ELECTRIC KETTLE WIRING DIAGRAM...
  • Page 15: Maintenance

    PEDESTAL ELECTRIC STEAM KETTLES MAINTENANCE Draw-off Valve Maintenance: To correct a leak at the draw-off valve, the source of the leak must first be determined. Leaks from around the valve stem are corrected by simply replacing the "0" ring. Faulty seating of the valve stem disc against the valve body seat may cause dripping from the valve even when the valve is tightly closed.