Evacuation (Plastic Hood) - Lippe Lift T80 Operation Manual

Table of Contents

Advertisement

4.7.4
Evacuation / by technical personnel only (version with plastic hood)
Proceed as follows in order to help the operator out of the platform lift:
 Press the EMERGENCY STOP button (p.8/item 3) on the platform.
 Remove the cap on the uphill side of the front cladding using a screwdriver
or similar.
 Push the visible bolt forwards. The uphill side safety barrier can then be
raised manually at the same time.
 The operator can now be helped out at the uphill side.
The platform must be folded up by hand so that the platform lift does not block the
staircase (see 4.5.2).
In order to gain access to the main switch on the plastic version, the screws must be
removed from the hood, after which the hood can be removed in an upward
direction.
Operating instructions T80PL 2010
18/21
Abdeckkappe
(01/2010)