Technical data:

1.1
Permissible loading capacity:
Continuous sound pressure level:
Vibrations:
Speed:
Platform voltage:
Battery charger voltage:
1.2

Ambient conditions:

Temperature range:
Rel. humidity:
Testing obligations
1.3
Whether or not the T80 platform lift is subject to an obligatory test depends on the respective
national regulations and is the user's responsibility. These regulations must be checked and
adhered to. In Germany, a test is obligatory for systems with a lifting height of ≥ 3m.
In each case, proof must be provided and documented in accordance with EN81-40 before the
first use.
The T80 platform lift is to undergo maintenance in accordance with the maintenance instructions
at least once per year. We recommend that you take out a service contract with your dealer.
2.

Intended purpose of use

The T80 platform lift is intended for the transport of wheelchair users and/or people with reduced
mobility.
The platform travels between fixed access points along a permanently installed rail, which can be
implemented straight or curved. The platform is guided over the stairs or an accessible inclined
surface by the running rail.
The system may only be operated by persons who have been instructed how to do so.
2.1
The following transport profiles are foreseen:
1. Transport of one person sitting in a wheelchair
2. Transport of one person sitting on the folding seat.
3. Transport of one person standing on the platform, provided that there is sufficient
headroom and that the person has sufficient standing stability and can hold the hand grips
securely (a separate set of documents is required, available on enquiry).
4. Transport of an additional person, provided that there is sufficient room on the platform
and that the permissible loading capacity is not exceeded. Point 1 or point 2 is to be
observed regarding this.
Operating instructions T80PL 2010
max. 300 kg
< 70 dB (A)
< 0.5 m/s² (measurement inaccuracy ± 3%)
approx. 0.1 m/s
24 V DC
230 V AC (55W)
-20 °C to +60 °C
max. 100%
5/21