Programming
Tea Dilution Stir (Factory set to ON).
Tea Dilut Stir
Press  to Select. Press < or > buttons, to toggle between OFF and ON. Press  to set.
Tea Pulse Brew (Factory set to OFF).
Press  to Select. Press < or > to select ON, OFF or D. D is a manual adjust from 1 to 20 pulses with an ON time
Tea Pulse Brew
from 5 to 150 seconds and an OFF time from 5 to 150 seconds.
Tea Fast Brew (Factory set to OFF).
Tea Fast Brew
Press  to Select, press < or > to choose ON or OFF. Selecting ON will start hot water spraying in the brewcone first
and then 1 minute later the dilution water will start to flow.
Tea Half Batch (Factory set to OFF).
Tea Half Batch
Press  to Select. Press < or > buttons, to toggle between OFF and ON. Press  to set.
Tea Drip-Out (Factory set to OFF)
Tea Drip-Out
Press  to Select. Press < or > to adjust time. Settings are OFF, up to 15 minutes, at one minute increments.
Temperature (Factory set to 204ºF)
Press  to Select. Press < or > to increase or decrease setting. Temperature range, from 170ºF to 208ºF in 2-degree
Temperature
increments.
Energy Save Mode (Factory set to OFF)
Press  to Select, < or > ON, OFF or ON 140ºF ,  to set. When in ON, unit will automatically shut off 4 hours from
Energy Save Mode
last brew. When feature is OFF, unit does not have the energy saving mode.
In the ON 140ºF position, temperature goes down to 140ºF. if unit has not brewed in 4 hours. This feature will save
energy by maintaining a lower temperature in the tank during periods of non-operation.
Brew Count Odom.
Press  to Select, Shows total gallons and total brew cycles on the unit. Press ex or Reset Brew Count Total.
Brew Count Odom
Brew Count Total
Brew Count Total
Press  to Select, Shows total gallons and total brew cycles on the unit. Cannot be reset.
Cold Brew Lock (Factory set to 5º F)
Press  to select, < or > to select desired setting (CBL 5, 15 or OFF), to set.
Cold Brew Lock
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point.
The first setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of
set point for the Ready to Brew message, however it will brew at any temperature.
Master Reset
Master Reset
Press  to display Are You Sure? Then < for Yes, > for No. When Master Reset is used, the all of the menu selec-
tions in the UCM return to factory defaults.
Service Call (Phone number Factory set to 1-800-000-0000)
Service Call
Press  to display number and change number or < to move place and EX to exit when complete. This number will
be displayed during a Heating system SENSOR ERROR or during a WATER ERROR.
Access Code (Factory set to 1-2-3-4)
Access Code
Press  to display number and change number, (the number can be changed 1 to 4) or < to move place and ex to exit
when complete.
Continued on Page 4