Programming
Banner Name (Factory set to CURTIS)
Banner Name
Press  to display letters and change letters or < to move place and EX to exit when complete
This feature allows up to 14 letters to be programmed for company name or regional name. Programming all blanks
disables Banner Name. If programmed, Banner Name is displayed every 5 sec. on and off.
P-Maintenance (Factory set to OFF)
P-Maintenance
Press  to Select, Set gallons brewed to indicate P-Maintenance. Press < or > to adjust from Off to 3000 gallons.
Press  to exit.
Beeper On/Off (Factory set to ON)
Beeper On/Off
Press  to display ON or OFF. Pressing either < or > toggles between on and off.  to set. When ON, this feature
allows you to hear a short beep each time a button is pressed.
Quality Timer (Factory set to OFF)
Quality Timer
Press  to Select. By pressing < or > buttons, you can increase and decrease time. Setting range is from 0 to 10
hours in 1 hour increments. Press  to set. Expired time indicated by audio alarm and flashing "Quality Timer".
Display Brew Time (Factory set to ON)
Display Brew
Time
Press  to Select. Pressing < or > toggles between ON and OFF.
Display Messages (Factory set to ON)
Display Messages
Press  to display ON or OFF. Pressing either < or > toggles between on and off. This feature allows the operator to
select the message "Rinse Server Before Brewing". This will be displayed any time the unit is not brewing.
Model Select (Factory set to 1/Half Batch)
Model Select
Press  to Select. Pressing < or > toggles between 1/Half Batch and 3-Batch.
Exit
Exit
Press  to select, exits program mode and returns unit to operation. Pressing > returns you to Tea Recipes.
Tank Temperature Check
Turn on brewer at the control panel ON/OFF button. Press and hold
will be displayed (temperature in heating tank).

Error Message

With G3/Gold Cup Series brewers, there are three error messages that can appear on the screen to advise the user of a malfunction. If one of
these error messages appear, the brewer will lock up and stop functioning until the error is corrected.
An error message will occur under the following conditions:
1. Water level fill error or overflow. This error message occurs when the inlet valve solenoid has been on for more than
(800) 000-000
10 minutes. This error message also occurs when the valve is refilling the tank during a brew cycle for more than 1½
Water Level Err
minutes.
(800) 000-000
2. Water temperature control system error. An open probe or a break in the temperature control circuit is detected.
Sensor Err
The screen may display a phone number to call for service. After the malfunction is corrected, the error message must be
cleared. To reset the control panel and return to normal operation, press  for 5 seconds.