Gas Igniter; Gas Regulator Valve; Gas Flame Detector; Thermostat Cutout - Automatic Reset (Gas) - Fisher & Paykel smartload DEGX1 Service Manual

Hide thumbs Also See for smartload DEGX1:
Table of Contents

Advertisement

3.6

Gas Igniter

Part Number
Cold Resistance
Typical Temperature
Minimum Temperature
Maximum Temperature
3.7

Gas Regulator Valve

Combination gas pressure regulator and dual automatic
gas valve.
Part Number
Voltage Rated
Resistance Across Terminals
1 & 2
1 & 3
3 & 4
Orifice
Regulated pressure
3.8

Gas Flame Detector

Part Number
Voltage Rated
Contacts normally closed, open with heat.
3.9
Thermostat Cutout – Automatic Reset (Gas)
Part Number
Type
Trip Temperature
Reset Temperature
395188
40 - 200 Ohms
2399°F (1315°C) @ 120V
1805°F (985°C) @ 80V
3092°F (1700°C) @ 132V
395369
120 Volts AC 60 Hz
1.4 kOhms
560 Ohms
1.3 kOhms
#43
3.5" H
O
2
395194
120 Volts AC 60 Hz
395192
SPST
o
o
F ± 5
(110°C ± 3
230
o
o
F ± 8
(95°C ± 4.5
203
- 22 -
o
)
o
)

Hide quick links: