TDK-Lambda 203 Operator's Manual
TDK-Lambda 203 Operator's Manual

TDK-Lambda 203 Operator's Manual

303 ale series 2 high voltage power supply
Table of Contents

Advertisement

Quick Links

OPERATOR MANUAL FOR
303 Series 2 High Voltage

POWER SUPPLY

Document: 83489011 Rev A
TDK-LAMBDA AMERICAS
405 Essex Road, Neptune, NJ 07753
Tel:
Fax:
Web:
www.us.tdk-lambda.com/hp
(732) 922-9300
(732) 922-1441

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 203 and is the answer not in the manual?

Questions and answers

Summary of Contents for TDK-Lambda 203

  • Page 1: Power Supply

    OPERATOR MANUAL FOR 303 Series 2 High Voltage POWER SUPPLY Document: 83489011 Rev A TDK-LAMBDA AMERICAS 405 Essex Road, Neptune, NJ 07753 Tel: (732) 922-9300 Fax: (732) 922-1441 Web: www.us.tdk-lambda.com/hp...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Table of Contents GENERAL INFORMATION ................1-1 INTRODUCTION....................1-1 203 and 303 OVERVIEW ..................1-1 1.2.1 FEATURES ........................1-1 1.2.2 BENEFITS........................1-1 1.2.3 APPLICATIONS: ......................1-1 CAPACITOR CHARGING TECHNOLOGY ............1-2 CONTINUOUS DC OPERATION ................1-2 ADDITIONAL FEATURES: ..................1-2 SAFETY PRECAUTIONS..................1-3 SCOPE OF THIS MANUAL ..................1-4 MODEL NUMBER FORMAT ..................1-4...
  • Page 4 TABLE OF CONTENTS CONNECTING THE HIGH VOLTAGE OUTPUT ..........4-16 CONTROLS, INDICATORS, CONNECTORS..........5-1 FRONT PANEL LAYOUT (L Model) ...............5-1 HV ON (Ref 1)......................5-2 OUTPUT STATUS LEDs (Ref 2) ................5-2 5.3.1 HV ON LED ........................5-3 5.3.2 HV OFF LED ........................5-3 5.3.3 INHIBIT LED........................
  • Page 5 Remote Operation with INHIBIT..................7-19 Parallel Operation....................7-20 7.3.1 Parallel system comprising 203/303L supplies ............. 7-20 7.3.2 Parallel system comprising both 203/303L and 203/303S supplies ......7-21 7.3.3 Parallel system comprising 203/303S supplies ............. 7-21 APPLICATION NOTES ................8-23 List of Figures 4-1 203/303L F ..................
  • Page 6 ANEL ONTROLS AND NDICATORS ODEL 5-3 F (S M ) ..........5-9 ABLE RONT ANEL ONTROLS AND NDICATORS ODEL 5-4 203/303L R ................. 5-11 ABLE EAR PANEL UNCTIONS 6-1 203/303 R ............. 7-17 ABLE EMOTE NTERFACE ESCRIPTION 83489011 Rev A...
  • Page 7: General Information

    LEDs. The "S" Models have been designed to operate as a slave unit to the "L" Models or in systems where local control is not a requirement. As many 203 or 303 supplies as required, can be connected in parallel to provide greater output power.
  • Page 8: Capacitor Charging Technology

    The flexible design of the 203 and 303 allow the units to be ordered with (L model) or without (S model) the front panel controls and meters. The front panel controls are ideal in applications where local control and readbacks are necessary, such as R&D, labora-...
  • Page 9: Safety Precautions

    Please take care to refer to the correct information for your unit. SAFETY PRECAUTIONS All 203 and 303 power supplies are designed to mini- mize the risk of fire or shock hazard. This instrument received comprehensive mechanical and electrical in- spection prior to shipment.
  • Page 10: Scope Of This Manual

    14. No cleaning is required. SCOPE OF THIS MANUAL This manual is used for installing and operating the 203 and 303 Series 2 Power Supply with a revised front panel layout shown in Figure 4-1. For older model 303 supplies refer to manual part number 83489009 which can be found on our web site.
  • Page 11 GENERAL INFORMATION 203/303( model (voltage) - (polarity) - (mode) - (input) - (options) Model (L, or S) Output Voltage Range kV POS or NEG Polarity Mode AC INPUT VOLTAGE OPTIONS Input Suffix Capacitor 5V Programming Standard Blank Charging 432-528 VAC,...
  • Page 12 GENERAL INFORMATION NOTES: 83489011 Rev A...
  • Page 13: Specifications

    SPECIFICATIONS SPECIFICATIONS Output Power MAXIMUM OUTPUT POWER RATING AC INPUT MODE VOLTAGE MODEL 203 MODEL 303 Cap Charging 20kJ/sec av, 25kJ/sec pk 30kJ/sec av, 37.5kJ/sec pk 432-528 VAC, 50-60 Hz, 3 Continuous DC 30kW 50kW Cap Charging 20kJ/sec av, 25kJ/sec pk 25kJ/sec av, 32.5kJ/sec pk...
  • Page 14: Input Power

    SPECIFICATIONS Input Power: MAXIMUM INPUT CURRENT AC INPUT VOLTAGE MODEL 203 MODEL 303 40A/Phase (Cap charging) 60A/Phase (Cap charging) 432-528 VAC, 50-60 Hz, 3 60A/Phase (Continuous DC) 98A/Phase (Continuous DC) 47A/Phase (Cap charging) 71A/Phase (Cap charging) 360-440 VAC, 50-60 Hz, 3...
  • Page 15: 2.16 Water Fittings

    SPECIFICATIONS 2.16 Water Fittings 1/4 inch NPT male threaded pipes 2.17 Weight 190 lbs. (86.4 kg) approx. 2.18 Shock and Vibration Unboxed 0.5 g. Factory packing 2.0 g 2.19 Shipping Gross weight with packing material: 240 lbs. (109 kg) approx. Size: 27"W X 21"...
  • Page 16 SPECIFICATIONS 2-10 NOTES: 83489011 Rev A...
  • Page 17: Out-Of-Box-Inspection

    1. With AC power OFF and disconnected, connect an appropriate load capacitor to the power supply output cable. 2. Prepare to charge the capacitor. NOTE: Operating a 203 or 303 power supply into an open circuit (no load operation) will instantly damage the power supply's H.V.
  • Page 18: Contacting Tdk-Lambda Americas Customer Service

    The supply and the coolant filled HV assembly should not be opened unless advised by TDK-Lambda Americas personnel. The coolant filled HV tank has been cleaned and the hermetically sealed at the factory, opening the supply or the assembly will void the facto- ry warranty, and may compromise performance.
  • Page 19: Installation

    Never install the 203 or 303 so only the front panel screws support its weight! The 203/303 must never be installed without support in the back or sides of the unit. The 203/303 should be mounted on heavy-duty chassis slides –such as General Devices CTS-124- or on a suitable shelf or supports inside the rack.
  • Page 20: Ventilation Requirements

    TB 1 AC INPUT 3.5” (89mm) Figure 4-2 203/303 Rear View VENTILATION REQUIREMENTS Ensure there is at least 5 inches (12.5 cm) of clearance at the rear of the unit for air- flow, cables and water lines. If the power supply is to be installed in an enclosed system, care must be taken to ensure the ambient inlet air to the power supply does not exceed the maximum operating temperature of 55°C.
  • Page 21: Ac Power Connection

    TDK-Lambda Americas standard warranty. The customer’s AC power line connects to the 203/303 via a UL/CSA approved 5 posi- tion terminal block on the rear panel of the unit (see Figure 4-3). Only use a power cable with the correct voltage and current rating (see Table 4-1).
  • Page 22: Connecting The High Voltage Output

    Always use the HV connector and cable provided with the power supply or an equivalent substitute provided by TDK-Lambda Americas. Fully insert the connector end of the HV cable and tighten the locking nut only "hand tight". When operating above 20kV and 200Hz rep rate a silicone grease (such as Dow Corn- ing DC-4) must be applied to the HV cable before insertion into the HV connector.
  • Page 23: Figure 4-4 Typical Load Circuit Connection

    Generally, a resistor in series with the HV output can be added to limit this current to an acceptable level. Refer to Application Note 517 (available from the factory or at www.us.tdk-lambda.com/hp) for more information. COOLANT WATER COOLANT WATER COOLANT WATER...
  • Page 24 INSTALLATION 4-18 NOTES: 83489011 Rev A...
  • Page 25: Controls, Indicators, Connectors

    CONTROLS, INDICATORS, CONNECTORS FRONT PANEL LAYOUT (L Model) The 203/303L series power supply is equipped with a fully instrumented front panel fea- turing output voltage control, voltage and current metering, and comprehensive status LEDs, along with local/remote mode keyswitch, and power on switch. The 203/303L can be operated locally from the front panel or remotely via the control connector located on the rear panel (see Section 7.2).
  • Page 26: Hv On (Ref 1)

    CONTROLS, INDICATORS, CONNECTORS DESCRIPTION NOTE SECTION HV ON Push Button Turns ON HV output Output Status Output Status LEDs Local Voltage Set 10 turn pot for setting output voltage in local mode Voltage Bar Graph Analog bar graph showing output voltage (%) Voltage Display Digital display of output or set voltage Current Display...
  • Page 27: Hv On Led

    CONTROLS, INDICATORS, CONNECTORS 5.3.1 HV ON LED The HV ON LED indicates that the HV output circuit is enabled and the supply will deliv- er output current if it is not inhibited by an external inhibit input. HV ON LED is active in local and remote modes.
  • Page 28: Voltage Bar Graph (Ref 4)

    An L model supply can simulate an S model with the key in the REMOTE position. 5.10 POWER SUPPLY STATUS LEDs (Ref 9) There are four distinct sets of status LEDs on the 203/303L/S front panel. Each group indicates the status of a specific section of the power supply. 5.10.1 STATUS LED GROUP 5.10.1.1...
  • Page 29: Autoinhibit (Normally Off)

    CONTROLS, INDICATORS, CONNECTORS 5.10.1.3 AUTOINHIBIT (Normally OFF) The AUTOINHIBIT feature shuts OFF or inhibits the output current when the capacitive load is discharged. This feature allows the HV switch in the external load circuit (if appli- cable) to better recover after a load switching event. The AUTOINHIBIT feature overcomes the need for the external inhibit signal in most cases.
  • Page 30: Internal Arc (Normally Off)

    5.10.3 COOLANT LED GROUP In the event of any coolant faults the user should verify installation orientation is in ac- cordance with Section 4.4 prior to contacting TDK-Lambda Americas. 5.10.3.1 FULL (Normally ON) When illuminated, this indicator signals that the high voltage tank in filled to the correct level with coolant.
  • Page 31: Purge Valve (Normally Off)

    CONTROLS, INDICATORS, CONNECTORS The coolant has a wide operating temperature range and is controlled and stabilized by the cooling water flowing through the high voltage tank. The maximum allowable tank temperature is 45°C, and the minimum is 15°C. This temperature range can be maintained by running normal tap water through the power supply at a rate of 2 gallons per minute (7.58 L/min).
  • Page 32: Bias Fault (Normally Off)

    CONTROLS, INDICATORS, CONNECTORS opened, disconnecting AC power from the HV circuitry. The INTERLOCK OPEN LED indication is reset automatically when the interlock circuit is closed (LED extinguished), but before power can be generated the fault condition must be reset by pushing the HV OFF push-button.
  • Page 33: Rear Panel Layout (L Models)

    5.13 respectively. 5.15 REAR PANEL LAYOUT (L Models) All of the interconnect and service connections for the 203/303L are located on the power supply rear panel. Figure 5-3 shows the rear panel layout and location of the var- ious connectors.
  • Page 34: Ear P Anel C Onnections

    COOLANT WATER inHg INTERLOCK/POWER ON HV OUTPUT 438-528 VAC 50/60 Hz COOLANT TB 1 AC INPUT Figure 5-3 203/303L Rear Panel Connections DESCRIPTION NOTE SECTION Inhibit BNC BNC socket for external inhibit signal 5.15.1 Coolant Water Inlet ¼ NPT male threaded coolant inlet pipe 5.15.2...
  • Page 35: Inhibit Bnc (Ref 1)

    SECTION AC input terminal AC input terminal block 5.15.11 Table 5-3 203/303L Rear panel Functions The function of each item in Table 5-3 is described in the following sections. 5.15.1 INHIBIT BNC (Ref 1) The inhibit BNC input is a standard BNC socket that allows an external connection to a pulse generator or control system and gives the user control of the power supply output current.
  • Page 36: Safety Ground

    See section 7.3 for more details. Note: The numbers in Figure 5-4 refer to Table 5-3. COOLANT WATER inHg INTERLOCK/POWER ON HV OUTPUT 438-528 VAC 50/60 Hz COOLANT TB 1 AC INPUT Figure 5-4 203/303S Rear Panel 83489011 Rev A...
  • Page 37: Optional Features

    The DC option is specified when a 203 or 303 series power supply is used to power a continuous DC load such as an RF tube, amplifier, DC-DC converter, or similar load where the output voltage and current is continuously on.
  • Page 38: Remote Sense (-Rs)

    CONTROLS, INDICATORS, CONNECTORS 6-14 Some examples of DC loads are; Tetrode Amplifiers Klystrons X-ray Tube Burn-In Gyrotrons DC-DC Converters Radar Systems Hard Tube Modulators REMOTE SENSE (-RS) The remote sense option can be specified when the output voltage accuracy or stability requirements of the application cannot be met by the internal voltage sensing compo- nents.
  • Page 39: Operating Instructions

    7-15 OPERATING INSTRUCTIONS The 203/303 power supply is designed for operation in two modes. The first mode is lo- cal, where the power supply is operated using the front panel controls. Local operation is only possible with the L model supply. The second mode is remote, where control sig- nals are passed via the 25pin remote connector.
  • Page 40: Remote Operation (All Models)

    For a full explanation of each control and indicator refer to Section 5. REMOTE OPERATION (All models) All 203/303 models are easily controlled through the 25 pin sub D-type remote interface connector located on the rear panel. The minimum required signals for remote control operation are;...
  • Page 41: Remote Control Signals

    To operate an L model in remote mode the front panel keyswitch must be in the REMOTE position. Before operating either a 203/303L or S in remote mode it must first be connected to a master supply, or an appropriate control system.
  • Page 42: Figure 7-1. External Remote Interface Circuit

    OPERATING INSTRUCTIONS 7-18 INTERLOCK INTERLOCK OPEN OPEN READY READY READY INPUT POWER FAULT INPUT POWER FAULT INHIBIT INHIBIT AUTOINHIBIT AUTOINHIBIT END OF CHARGE END OF CHARGE OVERLOAD OVERLOAD EXCESS REVERSAL EXCESS REVERSAL IPROGRAM 5k  5k  HV ON HV ON COOLANT LOW/FAULT OVER VOLTAGE OVER VOLTAGE...
  • Page 43: Remote Operation With Inhibit

    Although the AUTOINHIBIT signal offers the user the simplest remote programming method for the 203/303, the INHIBIT signal is commonly used to control the output cur- rent and offers greater flexibility, allowing the user to minimize the time at which the load capacitor remains at high voltage.
  • Page 44: Parallel Operation

    HV output cables together at the load. Either model 203/303L or 203/303S or any combination of units can be operated in parallel. If at least one model 203/303L is connected in a parallel system then the system can be operated without an external controller by using the 203/303L as a master supply in local mode.
  • Page 45: Parallel System Comprising Both 203/303L And 203/303S Supplies

    Parallel system comprising both 203/303L and 203/303S supplies For a system comprising both 203/303L and S units, a single L model should be operat- ed as a master in either local or remote mode. The other parallel supplies can be con- nected to the SLAVE 25-pin D-sub connector on the master unit rear panel (refer to Fig- ure 7-4).
  • Page 46 OPERATING INSTRUCTIONS 7-22 NOTES: 83489011 Rev A...
  • Page 47: Application Notes

    8-23 APPLICATION NOTES The 203/303 series power supplies are extremely powerful high voltage power sources and great care should be taken when connecting and operating these units. In order to aid installation design and number of application notes have been produced to aid the design engineer with certain load circuit component rating and selection.
  • Page 49 010481200rev3.sch-1 - Tue Nov 13 15:40:12 2012...
  • Page 50 010481200rev3.sch-2 - Tue Nov 13 15:40:12 2012...
  • Page 51 010481300rev7.sch-1 - Thu Jun 21 13:40:36 2012...
  • Page 52 010481300rev7.sch-2 - Thu Jun 21 13:40:36 2012...
  • Page 53 010481300rev7.sch-3 - Thu Jun 21 13:40:36 2012...
  • Page 54 010481300rev7.sch-4 - Thu Jun 21 13:40:36 2012...
  • Page 55 010481300rev7.sch-5 - Thu Jun 21 13:40:36 2012...
  • Page 56 010481300rev7.sch-6 - Thu Jun 21 13:40:36 2012...
  • Page 57 010481300rev7.sch-7 - Thu Jun 21 13:40:36 2012...
  • Page 58 010481300rev7.sch-8 - Thu Jun 21 13:40:37 2012...
  • Page 59 010481300rev7.sch-9 - Thu Jun 21 13:40:37 2012...
  • Page 60 010481300rev7.sch-10 - Thu Jun 21 13:40:37 2012...

This manual is also suitable for: