8. Replace the LAMP COVER PLATE back into place by securing (3) screws marked
"A", "B", and "C" illustrated by the
9. Be sure to reset the LAMP HOURS in the system menu to prevent the protection
circuitry from accidently shutting off the lamp during normal operation.
10. If the lamp protection circuitry has already been initiated and the LAMP HOURS is
not reset, the "Replace the Lamp" warning will continue to flash and fixture will
eventually shut down. To reset LAMP HOURS, see instructions on the next page.
LAMP HOURS RESET PROCEDURE
1. Activate the main menu by pressing MODE/ESC and toggle to "Information".
2. Press ENTER and press UP or DOWN to toggle to "Time Information".
3. Press UP or DOWN to toggle to "L-Timer Password" and press ENTER. Then press UP
or DOWN to enter the reset pass code, "038" and press ENTER to confirm. The
display will automatically revert to "L-Timer Password", next press UP or DOWN to
toggle down to "Clear Lamp Time".
4. Press ENTER and select "ON". The lamp timer has now been reset, press
MODE/ESC to exit the menu and return to the home screen.