Power Spot 700CMY™
EFFR
SPEC
MOVE
SPED
8.10.5 Display
DISP
Use this function to choose between different display indications. Use the
Up/Down-keys to select desired function and press Enter to confirm or Mode
to cancel and return to the menu.
D ON
REV
8.10.6 Fixture Temperature
TEMP
This function allows you to read out the actual fixture operating temperature.
Press the Enter button to select this function or the Mode to button to cancel
and return to the main menu. Normal operating temperature should range
between 85˚C and 95˚C. Operating temperatures between 96˚C and 104˚C
are considered critical. Temperatures above 105°C will send the fixture into
protect mode and automatically switch the lamp off, the lamp will remain off
until internal temperature drops below 95˚C. Outside surface temperature
should not exceed 45˚C.
8.10.7 Fan Control
©Elation Professionals® Los Angeles, Ca.
000 _ 255
000 _ 255
000 _ 255
000 _ 255
Display On/Off (If you've chosen off, the display will go out with-
in 15 seconds after the last input. The next key touch will
reactivate the display).
Rotates the display by a 180˚ - This may also be accomplished
by pressing both the "UP" and "DOWN" buttons at the same
time.
Effect wheel rotation
Lamp Off, Reset, ...
Movement
Speed for Pan/Tilt
-
wwww.ElationLighting.com
-
Page 29