TYPICAL CONNECTIONS
Use unshielded, 3 conductor
stranded wire per the table, when
extending the plug end of the IR Re-
ceiver Cable. (4 conductor provides
an extra wire for back-up if one of
the conductors gets damaged.)
When adding wire length, as a first option, use the BOT-1.0 (Diagram 17). This will allow
complete installation without having to cut the IR Receiver wires. The IR Parallel Block
(Diagram 18) has been included as a second option for that type of connection when
desirable. Confirm that the IR Signal, +12VDC and GND wires are properly connected
to both the BOT-1.0 or IR Parallel Block and the IR Router (Signal to Signal; +12 to +12;
GND to GND). Improper connection will affect performance and possibly damage the IR
Receiver. The Proficient One Warranty does not cover this type of damage.
While it is possible to make wired connections without the BOT-1.0, IR Parallel Block or
IR Router, it is not recommended. Their use will reduce installation time, help eliminate
errors, allow easy troubleshooting and permit easy system upgrades later, if needed.
8" Receiver Cable
(Do Not Add Length!)
Electronics Module
6' Reveiver Cable
(OK to Add Length)
Diagram 17 - Extending the Plug End of the IR Receiver Cable
GND (RING)
+12VDC (SLEEVE)
IR SIGNAL (TIP)
Diagram 16 - 3.5mm Stereo Mini Plug & Wire Pin-Out
PROFICIENT ONE
IR Receiver
Hand Held
IR Remote
BOT-1.0
IR Terminal
3-Conductor
Extension Cable
(unshielded)
REMOTE ROOM
IR WIRE LENGTH
UP TO 200' (61m)
UP TO 600' (183m)
UP TO 2000' (610m)
UP TO 5000' (1524m)
IR Dual
Flasher
PTP-1.0
IR Power
Supply
12VDC Regulated
500mA
12
IR WIRE GAUGE
24 AWG
22 AWG
20 AWG
18 AWG
GOLD = +12V
RED = GND
BLUE = IR
DVD
IR Flasher
w/red LED
Cable
IR Flasher
w/red LED
A/V Receiver
PTP-1.0
Point to Point
Jumper Cable
To 120V AC
(unswitched)
MAIN ROOM